Actions

%1.exp

From Zenitel Wiki

Revision as of 13:38, 26 May 2015 by Roarl (talk)
Returns the User defined parameter as enterened in AlphaPro, Users & Stations -> UDP tab.
  • %2.exp is used to read the User Defined Parameter of the "Related-to" station. In AlphaNet this is supported when the station is in the local exchange where the event is executed.
UDP (User Defined Parameter) is configured in AlphaPro


Formating of the returned data is supported.


Note: The macro cannot be followed by a character a-z or A-Z. 
This will result in a syntax error. Either a space character must be used, 
or the macro must be followed by empty brackets () if space cannot be used.

Examples, assuming that the UDP field contains "4321":

Expression   Returned value
----------   --------------
%1.exp     = 4321
%1.exp Ma  = 4321 Ma
%1.exp()Ma = 4321Ma
%1.expMa   = Syntax error





Back to Event_Handler#List_of_context_parameters.