INCA Station Restore Factory Defaults
From Zenitel Wiki
The unit can be set to use either Static IP or DHCP. This procedure is applicable for the stations:
- IP Substations - 1008041100/1008051000
- IP Video Door Stations - 1401110100/1401110200
- IP Master Station Kit - 1008093000 - A push button must be connected between pin 1 and pin 4 on connector P4.
- The IP Substation Kit - 1008090200 - A push button must be connected between pin 1 and pin 4 on connector P4.
Procedure:
- While pressing the call button, power up the station and keep the button pressed.
- Release the button after exactly 2 flashes of the LED.
- Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
- Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
- Release the button and the station will restart with the factory default settings.
Factory default values:
- Station Mode: Pulse
- Station IP address: 169.254.1.100 or DHCP
- Username: admin
- Password: alphaadmin
* Software 01.06 and earlier: Username/password isADMIN/alphacom