The IP DualDisplay station can be reset to Factory Default settings in two ways:
- From the display menu
- By a power boot sequence
Contents
The Station Menu is available when the IP Station is in offline mode. i.e. not registered to the server.
- Press the Setup button beneath the display
- Enter the password 1851 and press the Ok button.
- Navigate to Load defaults and press the Sel button.
- Press the Sel button to load factory defaults.
The station will now restart with factory settings.
By a power boot sequence
The Factory Default procedure can be used to either set the station to use a Static IP address, or to use IP address from a DHCP server.
Restore with Static IP
- Press and hold the Privacy button. Power up the station
- When the station LED starts blinking, release the privacy button after exactly 2 blinks.
- Let the LED blink for exactly 2 more times, then press the button again.
- Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
- Release the button and the station will restart with the factory default settings.
Factory default values:
- Station Mode: Pulse
- Station IP address: 169.254.1.100
- Username: admin
- Password: alphaadmin
Restore with Activated DHCP
The DHCP option is available from software version 01.07.
- While pressing the call button, power up the substation.
- When the substation LED starts blinking, release the call button after exactly 2 blinks.
- Let the LED blink for exactly 4 more times, then press the button again.
- Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
- Release the button and the substation will restart with the factory default settings.
Factory default values | |
---|---|
Station Mode | Pulse |
Station IP address | determined by DHCP server |
AlphaCom IP address | 169.254.1.5 |
Username* | admin |
Password* | alphaadmin |
* Software 01.06 and earlier: ADMIN/alphacom)