Actions

ST STATE

From Zenitel Wiki

Revision as of 15:10, 3 October 2019 by Nikica (talk | contribs)
AI.png
ST_STATE 0x009A 154 AMC 10.23
Response to the GET_ST_STATE message.
Current status of a station

Illegal station or no more stations available will return ST_STATE without parameters

1 UINT2 1 -> 552: Station Physical Number
2 NET_OBJ_REF{ECL_STATION} Default user Directory Number
3 TEXT16 Default user Display text
4 UINT4 State bitmap Bits:

1: 0 = Free, 1 = Busy

2: 0 = A station, 1 = B station in communication.(Param 8. describe related station)

3: 0 = M-rel, 1 = M-pres

4: 0 = Hook on, 1 = Hook off

(*)5: 0 = privat off, 1 = private on

6: 0 = No mail, 1 = Mail in queue

7: 0 = Tone test OK, 1 = Failed. (11.1.3.2)
25-32 = UDP groups as bitmap.

5 UINT1 Line State

0 Board not present

1 SLI board present, no station

2 SLI board present, station with failure

3 Station connected to SLI board

16 IP station configured, not connected

17 IP station connected but not authorized

18 IP station connected and registered OK, auth not required

19 IP station connected and authorized

20 IP station connected but no license available

6 UINT2 Station RCI bitmap

1: RCI 1, 0 = off, 1 = on

2: RCI 2....

7 UINT2 Station RCO bitmap

1: RCO 1, 0 = off, 1 = on

2: RCO 2....

8 NET_OBJ_REF (Empty REF in no conn active)Related station in connection.
9 UINT2 (0 if no conn active)Connection reference as given in CONN_STATUS_BC
10 UINT1 (0 if no conn active)CALL status as given in CALL_STATUS_BC
11 UINT4(11.2.3.7) IP station hardware type.

IP HW type ID :
32800 0x8020 IP Dual Display

32801 0x8021 SUB station board 1

32802 0x8022 SUB station board 2

32803 0x8023 Console board

32804 0x8024 IP Desktop

28708 0x7024 SoftClient

32806 0x8026 IP-ARIO

00256 0x0100 SIP Phone

00257 0x0101 IP Dummy station

00000 0x0000 Analog station/no station

12 UINT1(11.2.3.7) Station type as defined in AlphaPro

Station type codes:
0 Master Station

1 Sub Station

2 PNCI

3 CRM station

4 InterGuard

5 DualDisplay

6 Custom

7 SIP station

8 Conference Mixer

13 UINT4(11.2.3.7) IPARIO status flags

Bit number:
0 Amplifier 1, fault relay
1 Amplifier 2, fault relay
2 Amplifier 1, 24VDC fault
3 Amplifier 2, 24VDC fault
4 Amplifier 1, Speaker Loop Monitoring 1
5 Amplifier 2, Speaker Loop Monitoring 2
6 Amplifier 1, XLR Connected
7 Amplifier 2, XLR Connected

10 IPARIO down
11 $PA_CMD "ACK"
12 --$PA_CMD "CLEAR"
13 Fault led steady. (Fault acknowledged)
14 Fault led blinking. (Fault not acknowledged)


Response to: GET_ST_STATE
(*) Not implemented yet


ST_STATE will be reported to the OPC server when:

  • Mail queue changes from 0 to 1 or 1 to 0.
  • Line state changes(Line fault etc)
  • RCI changes on IP station.
  • RCO changes on IP station.

Note: This command require an OPC Server license

Back to AlphaNet message list