The IP Vandal Resistant Substation with TKIE has the possibility to be fitted with a tamper switch. Making it possible to raise an alarm if the station is dismounted from the backbox.

Tamper Switch
(1008091010)

Configuration

For a single station

In AlphaPro, create this event for the Tamper Switch, setting the substation as the event owner:

Event handler configuration


Action commands:

$STM L110 L101 U145 'TAMPER CELL 10'


  • $STM - Sendt Text Message
  • L110 - From 110
  • L101 * To 101
  • U145 - Priority level 145
  • TAMPER CELL 10 - Text

For all stations

In AlphaPro, create this event for the Tamper Switch, and configure UDP Group 8 as event owner:

Event handler configuration


Action commands:

$STM L%2.dir L101 U145 '%1.nam'


Verify that I/O 3 is set as an input

The IP Substation must have I/O number 3 defined as an input (default).

Advanced AlphaCom -> I/O Settings





Mounting

Mounting instruction on Tamper Switch for IP Vandal Resistant Substation TKIE

Step 1: Remove the two nylon nuts shown below

Tamper1.png


Step 2: Attach the supplied spacers

Tamper2.png


Step 3: Mount the tamper switch board

Tamper3.png


Step 4: Move the button GND wire from the the TKIE board to the tamper switch board

Tamper4.png


Tamper5.png


Step 5: Use the supplied wires to connect GND and Input 3 as shown below

Tamper6.png