SEND MAIL
From Zenitel Wiki
SEND_MAIL | 0x0031 | 49 | AMC 05.00 | |
---|---|---|---|---|
$SM L101 L102<br\>$SM L101 L102 U100 NM18 GV U1<br\>$SM L101 L102 U100 NM26 GV U0<br\>$SM L101 L102 U100 NM17 GV U1 'my name' U0 | Call Request mail (from AMC 08.11)<br\>Call Request mail<br\>‘Temperature Alarm’<br\>Call request, user defined name text | |||
Send a mail message to an intercom station.<br\><br\>
From AMC 08.11 most parameters can be left out. Default values correspond to Normal priority Call Request.<br\> AlphaNet: Be aware of which exchange fills in default parameters, see page 70 | ||||
1 | NET_OBJ_REF<br\>{ECL_STATION} | Sending station.<br\>Null value allowed (e.g.for technical alarms). | ||
2 | [[NET_OBJ_REF<br\>{ECL_STATION,<br\>ECL_ST_GROUP}]] | Receiving station or local group.<br\>.<br\>. | ||
3 | UINT1<br\>(optional 08.11) | Mail Priority 0 - 255<br\>Default value: 100. | ||
4 | NET_OBJ_REF<br\>{NRF_LOCAL_DIRNO<br\>ECL_MAIL<br\>ECL_MAIL}<br\>(optional 08.11) | Which Mail Message or Null if no message. See page 17.<br\>-> Mail message with directory number.<br\>-> Call Request, mail individ 17 (alarm) and 18 (normal).<br\>-> Technical alarm, mail individ 19-30. <br\>Default value: 18. | ||
5 | NET_OBJ_REF<br\>(optional 08.11) | Extra parameter (time / date / phone number) in DIGIT_STRING format. <br\>Default value: Null. | ||
6 | UINT1<br\>(optional 08.11) | Mail Flags:<br\>bit 1 (value 1) = the mail is a call request. The station receiving the mail will respond with SET_CALL_REQ_MODE to the sender station. <br\>bit 2 (value 2) = the mail is sent to a group of stations and you want the mail deleted from all queues once the mail has been read by a station. <br\>Combinations of bits allowed.<br\>Default value: 1. | AMC 07.00 | |
7 | TEXT16<br\>(optional 07.60) | Name of sending station (16 character).<br\>Default value: Sending station’s name. | AMC 07.00 | |
8 | UINT1<br\>(optional 07.60) | User Defined Properties (UDP) of the sending station. <br\>Default value: 0. <br\>Note: If Parameter 7 is used, this parameter MUST be filled in also. | AMC 07.00 | |
9 | UINT1<br\>(optional) | Hop Count. AlphaNet: Used to avoid endless mail forwarding. Incremented by AMC, discarded when too large.<br\>Default value: 0. | ||
Response: | SEND_MAIL_ACK, SET_CALL_REQ_MODE |