Activate RCO output at remote station feature
From Zenitel Wiki
58 FEAT_PULSE_PEER_RCO
Param1 | Description |
---|---|
?? | Activate Remote Control output at peer station |
During connection: Generates event "Door Opening" on other station. |
Feature: | Remote control (Door opening) |
Default directory number: | 6 - during conversation |
Feature number: | 58 |
Parameter 1: | 0 (N/A) |
Description: | During conversation press 6 to generates event "Door Opening" on other station. A station can activate the other station's remote control device (RCO) by pressing and releasing digit 6 during connection. If the station has remote control assigned, a success tone is given. The feature generates an event to the Event Handler, where the actual remote control takes place. The feature has timing so that the event is reported OFF after 3,5 seconds (programmable). |