Actions

WK20 - Applications

From Zenitel Wiki

Revision as of 08:24, 9 May 2012 by Asle (talk) (Equipment List)

Amplified Calling Tone with answer in station

Figure 1.1: Amplified Calling Tone with answer in station

Amplifier disabled by station

Feature Description

The audio signal of incoming calls can be amplified as an extra indication of the call. The feature require a station and a separate speaker for distribution of the amplified calling tone. It is not possible to answer the call through the separate speaker.

Operation

As a call is made to the station, the corresponding RCO triggers a relay which controls the amplifier, and makes it turn on. This is repeated for every calling tone if the station is in PRIVATE position. When the call is answered the amplifier will be switch on and off by the callers M-key. To disable the amplifier the called party lifts the handset or presses a digit on the keypad.

Equipment List

  • Power Amplifier WK20, item 1000614100
  • 8-20 Ohm loudspeaker, e.g. item HP-15 (8 ohm/15W)
  • 24VAC transformer
  • Multi Relay Board MRBD, item 1009970200
  • Power Distribution Board PDB, item 1009970100 (This Board is only required in an XE26 installation. XE7 and XE20 comes with +24VDC outputs.)
  • Station

Installation

  • Mount the Amplifier Board WK20 in a suitable position near the loudspeaker.
  • Mount the local power supply and connet it to the Amplifier Board WK20 point 8-9
  • Remove resistor R10
  • Run the wires according to figure 1.1

Programming

The amplifier can be switched on and off by an RCO command in the Event Handler.

How to configure the relay operation:

  • In Users & Stations select the loudspeaker directory number in the list box, and press the button 'Events'. 'Insert' a new event with the following attributes:
Figure 1.2: Event to switch amplifier ON/OFF


Event Owner: The loudspeaker directory number
Event type: 1 - Audio
Subevent: 12 (Press 'Details' to select "Incoming calls")
When change to: ON or OFF
When related to: (not used)
Action: RCO 10

RCO 10 is used as an example. Use the RCO number you have assigned to the loudspeaker physical connection.


Amplified Calling without answer

Amplifier constantly on

Figure 2.1: Amplified Calling without answer. Amplifier constantly on

Feature Description

The feature enables amplified calling through a loudspeaker without having a station connected.
Calling is done by dialling the directory number of the loudspeaker. Speak after hearing the calling tone. Answer is not possible. Cancel the call with the C-key.

Equipment List

  • Resistor 2.2kOhm
  • Diode 1N4148
  • Amplifier Board WK20 1000614100
  • 20-63Ohm loudspeaker
  • 24VAC transformer

Installation

  • Connect a resistor (2.2kOhm) in series with a diode (1N4148) between the c/d wires on a suitable place for the intended physical number.
  • Mount the Amplifier Board WK20 in a suitable position near the loudspeaker.
  • Strap point 1-7 and 2-3 on the Amplifier Board WK20
  • Mount the local power supply and connet it to the Amplifier Board WK20 point 8-9
  • Run the wires according to figure 2.1

Programming

No additional programming necessary.

Amplifier switched with the M-key

Figure 3.1: Amplified Calling without answer. Amplifier switched with the M-key

Feature Description

The feature enables amplified calling through a loudspeaker without having a station connected.
Calling is done by dialling the directory number of the loudspeaker. Press the M-key to speak. Answer is not possible. Cancel the call with the C-key.

Equipment List

  • Resistor 2.2kOhm
  • Diode 1N4148
  • Amplifier Board WK20 1000614100
  • 20-63Ohm loudspeaker
  • 24VAC transformer
  • Multirelay Board MRBD 1009970200
  • Power Distribution Board PDB 1009970100 (This Board is only required in an E26 installation. E7 and E20 has +24VDC outputs.)

Installation

  • Connect a resistor (2.2kOhm) in series with a diode (1N4148) between the c/d wires on a suitable place for the intended physical number.
  • Mount the Amplifier Board WK20 and 24VAC transformer in a suitable position near the loudspeaker.
  • Mount the Multirelay Board in close proximity to the exchange
  • The PDB board mounts on the back of the E26, and feeds the MRBD with +24VDC. (In case of an E7 or E20 exchange, +24VDC can be taken directly from a dedicated output.)
  • Run the wires according to figure 3.1

Programming

The amplifier can be switched on and off by an RCO command in the Event Handler.

How to configure the relay operation:

  • In Users & Stations select the loudspeaker directory number in the list box, and press the button 'Events'. 'Insert' a new event with the following attributes:
Figure 3.2: Event to control the amplifier on/off


Event Owner: The loudspeaker directory number
Event type: 1 - Audio
Subevent: 126 (Press 'Details' to select which types of audio. 126 means all types of audio)
When change to: ON or OFF
When related to: (not used)
Action: RCO 10

RCO 10 is used as an example. Use the RCO number you have assigned to the loudspeaker physical connection.


Amplified Calling with answer in separate microphone

Amplifier constantly on

Figure 4.1: Amplified Calling with answer in separate microphone. Amplifier constantly on

Feature Description

The feature enables amplified calling through a loudspeaker without having a station connected.
Calling is done by dialling the directory number of the loudspeaker. Speak after hearing the calling tone. Answer is possible through the microphone. Cancel the call with the C-key.

Eqipment List

  • Amplifier Board WK20 1000614100
  • 20-63Ohm loudspeaker
  • 24VAC transformer
  • Microphone Amplifier Board Dynamic with Relay MADR 1009960100
  • Dynamic microphone

Installation

  • Mount the Amplifier Board WK20 and 24VAC transformer in a suitable position near the loudspeaker.
  • Strap point 1-7 and 2-3 on the Amplifier Board WK20
  • Mount the Microphone Amplifier Board MADR in a suitable position near the microphone.
  • Run the wires according to figure 4.1

Programming

No additional programming necessary.


Amplifier switched with the M-key

Figure 5.1: Amplified Calling with answer in separate microphone. Amplifier switched with M-key

Feature Description

The feature enables amplified calling through a loudspeaker without having a station connected.
Calling is done by dialling the directory number of the loudspeaker. Press the M-key to speak. Answer is possible through the microphone. Cancel the call with the C-key.

Equipment List

  • Amplifier Board WK20 1000614100
  • 20-63Ohm loudspeaker
  • 24VAC transformer
  • Microphone Amplifier Board Dynamic with Relay MADR 1009960100
  • Dynamic microphone
  • Multirelay Board MRBD 1009970200
  • Power Distribution Board PDB 1009970100 (This Board is only required in an E26 installation. E7 and E20 has +24VDC outputs.)

Installation

  • Mount the Amplifier Board WK20 and 24VAC transformer in a suitable position near the loudspeaker.
  • Mount the Microphone Amplifier Board MADR in a suitable position near the microphone.
  • Mount the Multirelay Board in close proximity to the exchange.
  • The PDB board mounts on the back of the E26, and feeds the MRBD with +24VDC. (In case of an E7 or E20 exchange, +24VDC can be taken directly from a dedicated output.)
  • Run the wires according to figure 5.1

Programming

The amplifier can be switched on and off by an RCO command in the Event Handler.

How to configure the relay operation:

  • In Users & Stations select the loudspeaker directory number in the list box, and press the button 'Events'. 'Insert' a new event with the following attributes:
Figure 5.2: Event to control the amplifier on/off


Event Owner: The loudspeaker directory number
Event type: 1 - Audio
Subevent: 126 (Press 'Details' to select which types of audio. 126 means all types of audio)
When change to: ON or OFF
When related to: (not used)
Action: RCO 10

RCO 10 is used as an example. Use the RCO number you have assigned to the loudspeaker physical connection.


Amplified Calling with answer in separate loudspeaker

Amplifier switched with the M-key

Figure 6.1: Amplified Calling with answer in separate loudspeaker. Amplifier switched with the M-key

Feature Description

The feature enables amplified calling through a loudspeaker without having a station connected.
Calling is done by dialling the directory number of the loudspeaker. Press the M-key to speak. Answer is possible through an extra loudspeaker. Cancel the call with the C-key.

Equipment List

  • Amplifier Board WK20 1000614100
  • 20-63Ohm loudspeaker
  • 24VAC transformer
  • Microphone Amplifier Board Dynamic with Relay MADR 1009960100
  • Dynamic loudspeaker
  • Multirelay Board MRBD 1009970200
  • Power Distribution Board PDB 1009970100 (This Board is only required in an E26 installation. E7 and E20 has +24VDC outputs.)

Installation

  • Mount the Amplifier Board WK20 and 24VAC transformer in a suitable position near the loudspeaker.
  • Mount the Microphone Amplifier Board MADR in a suitable position near the dynamic loudspeaker.
  • Mount the Multirelay Board in close proximity to the exchange.
  • The PDB board mounts on the back of the E26, and feeds the MRBD with +24VDC. (In case of an E7 or E20 exchange, +24VDC can be taken directly from a dedicated output.)
  • Run the wires according to figure 6.1

Programming

The amplifier can be switched on and off by an RCO command in the Event Handler.

How to configure the relay operation:

  • In Users & Stations select the loudspeaker directory number in the list box, and press the button 'Events'. 'Insert' a new event with the following attributes:
Figure 6.2: Event to control the amplifier on/off


Event Owner: The loudspeaker directory number
Event type: 1 - Audio
Subevent: 126 (Press 'Details' to select which types of audio. 126 means all types of audio)
When change to: ON or OFF
When related to: (not used)
Action: RCO 10

RCO 10 is used as an example. Use the RCO number you have assigned to the loudspeaker physical connection.


Amplified Calling with answer in called loudspeaker

Voice direction switched with M-key

Figure 7.1: Amplified Calling with answer in called loudspeaker. Voice direction switched with M-key

Feature Description

The feature enables amplified calling through a loudspeaker without having a station connected.
Calling is done by dialling the directory number of the loudspeaker. Press the M-key to speak. Answer is possible through the called loudspeaker. Cancel the call with the C-key.

Equipment List

Installation

  • Mount the Amplifier Board WK20 and 24VAC transformer in a suitable position near the loudspeaker.
  • Strap point 1-7 and 2-3 on the Amplifier Board WK20
  • Mount the Microphone Amplifier Board MADR in a suitable position near the loudspeaker.
  • The PDB board mounts on the back of the E26, and feeds the MRBD with +24VDC. (In case of an E7 or E20 exchange, +24VDC can be taken directly from a dedicated output.)
  • Run the wires according to figure 7.1

Programming

The voice direction can be switched by an RCO command in the Event Handler.

How to configure the relay operation:

  • In Users & Stations select the loudspeaker directory number in the list box, and press the button 'Events'. 'Insert' a new event with the following attributes:
Figure 7.2: Event to switch the voice direction


Event Owner: The loudspeaker directory number
Event type: 1 - Audio
Subevent: 126 (Press 'Details' to select which types of audio. 126 means all types of audio)
When change to: ON or OFF
When related to: (not used)
Action: RCO 10

RCO 10 is used as an example. Use the RCO number you have assigned to the loudspeaker physical connection.


Amplifier and voice direction switched with the M-key

Figure 8.1: Amplified calling with answer in called loudspeaker. Amplifier and voice direction switched with the M-key

Feature Description

The feature enables amplified calling through a loudspeaker without having a station connected.
Calling is done by dialling the directory number of the loudspeaker. Press the M-key to speak. Answer is possible through the called loudspeaker. Cancel the call with the C-key.

Equipment List

  • Amplifier Board WK20 1000614100
  • 24VAC transformer
  • Microphone Amplifier Board Dynamic with Relay MADR 1009960100
  • Dynamic loudspeaker
  • Multirelay Board MRBD 1009970200
  • Power Distribution Board PDB 1009970100 (This Board is only required in an E26 installation. E7 and E20 has +24VDC outputs.)

Installation

  • Mount the Amplifier Board WK20 and 24VAC transformer in a suitable position near the loudspeaker.
  • Mount the Microphone Amplifier Board MADR in a suitable position near the loudspeaker.
  • Mount the Multirelay Board in close proximity to the exchange.
  • The PDB board mounts on the back of the E26, and feeds the MRBD with +24VDC. (In case of an E7 or E20 exchange, +24VDC can be taken directly from a dedicated output.)
  • Run the wires according to figure 8.1


Programming

The voice direction can be switched, and the amplifier can be switched on and off by an RCO command in the Event Handler.

How to configure the relay operation:

  • In Users & Stations select the loudspeaker directory number in the list box, and press the button 'Events'. 'Insert' a new event with the following attributes:
Figure 8.2: Event to switch the voice direction and switch the amplifier on and off


Event Owner: The loudspeaker directory number
Event type: 1 - Audio
Subevent: 126 (Press 'Details' to select which types of audio. 126 means all types of audio)
When change to: ON or OFF
When related to: (not used)
Action: RCO 10

RCO 10 is used as an example. Use the RCO number you have assigned to the loudspeaker physical connection.