Actions

1-3b. IP Stations – Substations (solution)

From Zenitel Wiki

Revision as of 16:46, 22 March 2011 by Asle (talk) (Configure the IP Substation)
System configuration



Configure the IP Substation

  • Perform a "Factory Default" setting on the IP Substation
    • Press the call button
    • While the button is pressed, connect the IP Substation to the PoE switch
    • Wait until the call LED of the station starts to flash
    • Release the call button for exactly two flashes
    • Push the button briefly
  • Assign the PC an IP address in the range 169.254.x.x
  • Connect the PC to the network switch
File:1-3b solution1.png
Accessing the IP Substations web page


  • When prompted, Save the changes. When asked for "Restart now" you can select "No".
  • Step to the menu selection AlphaCom IP and enter the following parameters:
Off-line menu: AlphaCom settings


  • When prompted, Save the changes.
  • Step to the menu selection Restart and activate a restart of the station

Configure the AlphaCom XE

  • In AlphaPro go to Users & Stations, and select physical number 37; 137 Station 37
  • Use the section on the right and change the configuration as follows:
AlphaPro: Users & Stations window


  • In AlphaPro go to Users & Stations, and select physical number 38; 138 Station 38
  • Use the section on the right and change the configuration as follows:
AlphaPro: Users & Stations window


  • Send the changes to the AlphaCom XE

SendChg.PNG






Related articles