Actions

1-4f. Main Features – Call Request (solution)

From Zenitel Wiki

Revision as of 12:55, 31 March 2017 by Asle (talk)
System configuration


Exercise

CRM - Control Room Master

  • Configure the Main Guard for call queing by setting station type to "CRM" (Control Room Master).
Set the Station Type = CRM. This will change the display into a four-line display, and it will be more suitable for call request handling


The display might look a bit strange after changing it to "CRM". If so, dial 789 to refresh the new display settings.

Call Request

  • The call button at the Entrance and at the Elevator should generate a Call Request to the Main Guard:
Program DAK 1 of the two substations to dial 623 + 400



Call Request - Hotline

  • 2 seconds after Mr. Galilei lifts the handset, a Call Request should be made to the Main Guard. The Call Request should be removed if the handset is replaced before answered:
Enable the "Hotline Call" function for Mr. Galilei


Program off-hook to generate a Call Request and on-hook to cancel the Call Request


In Exchange & System -> System, change the Hotline Call timer to 20 (2.0 sec)



Call Escalation

  • If the Call Request has not been answered within 20 seconds, the call should automatically be forwarded to the Reception


Automatic Search > Call Request


  • By activating the DAK key D1 at the Main Guard, new call requests should be forwarded to the Reception:
Program the first DAK key to dial 7870 + Reception. This will activate the Call Request forwarding








Related articles