Revision as of 09:20, 13 October 2016 by Roarl (talk) (Created page with "right|400px left|350px <br style="clear:both;" /> {| border="1" |Ethernet/Power|| 10/100 Mbps Ethernet RJ-45 port for...")
Ethernet/Power | 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line. |
Secondary Power | 24 VDC (16 – 48 V) secondary power is provided from an external adapter. |
Relays | There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W |
Input/Output | 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver. |
Audio Line Out | A balanced 600 ohm audio line out with induction loop signal |
Note! Use cables crimped with ferrules for terminal block connectors
- When the Turbine Station is connected to the network, its IP address is automatically obtained from a DHCP server or an IP address in the range 169.254.x.x will be assigned.
- To make the station speak its IP address, press the call button on the station.
Power Supply
The Turbine Compact Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line. If PoE is not available, the Turbine Compact Station can be connected to a 24 VDC local power supply.
Network Connection
There is one RJ-45 port located on the Turbine Compact station that is used for PoE/LAN Ethernet connection.
Input/Output Connections
There are 6 I/O connection options for the Turbine Compact Station. These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.
See also Turbine Compact Board Connectors