Camera Configuration

The camera is directly connected with the Turbine main circuit board and can be accessed through the ordinary IP-StationWeb.

After logging in to the TCIV navigate to Advanced AlphaCom -> Video

TCIV 1.PNG

Enable Video

  • Enables the internal video camera when checked

Lens distortion correction

Night mode

  • Enables night mode when checked

Zoom

  • Select the zoom of the camera. Values are 1x or 2.5x

Offset Left Right [-100 100]

  • Available when zoom is set to more than 1x. Determines the width of the image.

Offset Up-Down [-100 100]

  • Available when zoom is set to more than 1x. Determines the height of the image.

Color saturation [0 255]

  • Adjust the colorfulness of a color relative to its own brightness.

Contrast [0 255]

  • Contrast adjustment.

Brightness [0 255]

  • Brightness adjustment.

Backlight compensation

  • Available values 0-5. Default value = 2.

Camera IP address and port

  • IP address is fixed and equal to the TCIV IP address. Port (default 8090) can be changed.

Resolution and fps

  • Sets pixel resolution and framerate per second.

Enable HTTP basic authentication

  • Requires username and password to fetch video when checked (default admin/alphaadmin).