IP-LCM Connections
From Zenitel Wiki
Inputs
From the top left the inputs are numbered as pin 17 to pin 24. Each input has a corresponding input switch which toggles between closing contact and active input.
Outputs
From the left side the outputs are numbered as pin 17 to pin 24. Each output is a dual pole relay with normally open, normally close and common available on the pin header.
The bottom four outputs each has a corresponding switch. This allows forwarding power from the power forwarding connector to the relay normally open and common on each output.
Relay ratings:
- Outputs: DPDT (NO, NC, COM)
- Switched voltage: < 250VAC Rated (400VAC Max)
- Switched Voltage: < 2000 VA max
- Switching Current: < 8A rated (15A max, 4s)
Indicators
Each output has a LED which indicates if the output is active or not.
See here for ior information on the TKIS-2 kit connections