Flowire FCDC3 - Release Notes

From Zenitel Wiki

Revision as of 12:41, 20 May 2020 by Asle (talk | contribs)

Version 1.0.3.2 (2020-03-17)

Release Info

  • Name: vsf-fcdc3-1.0.3.2.zip
  • Description: vsf-fcdc3-1.0.3.2_fs_kernel can be installed on FCDC3
  • Version: 1.0.3.2
  • Date: 17.03.2020
  • Status: GA
  • Upgrade: See Flowire Software Upgrade Procedure

Files included in vsf-fcdc3-1.0.3.2.zip:

  • vsf-fcdc3-1.0.3.2_fs_kernel - For upload to web by users.
  • vsf-fcdc3-1.0.3.2_flash_image_960333PLC_REF.w - Complete image for JTAG/SPI burning at production.

New version vsf-fcdc3-1.0.3.2

vsf-fcdc3-1.0.3.2 is the first version released for General Availability.

vsf-fcdc3-1.0.3.2 fixes interoperability with FCDC1/2 when multiple clusters(MTN-2853).

Several improvements has been made to the web interface. All relevant settings are now listed on the front web page. See Changes.txt in zip file for details.

For more information about FCDC3 SW and HW visit FCDC-3.

Known issues

The "Backup/Restore settings" function in the web only include a few of the settings.


Important information

IGMP settings

As long as the system is using a managed switch, the following applies:

  • “IGMP querier” should be disabled in all Flowire units
  • “IGMPv2 compatability” should never be enabled in the Flowire connected to the system switch
  • “IGMPv2 compatability” should always be enabled in the Flowire connected to the field equipment

More information on how to configure the Flowire’s IGMP settings

CCo settings

For optimal availability in cluster configurations, use the CCo settings in Flowire web as follows:

  • Set the Flowire connected to the system switch to “CCo”
  • Set the Flowires connected to the field equipment to “Not CCo”

In Exigo A/B systems, clusters must be connected to either the A or the B system. Flowire does not support redundant connections to devices in a cluster.

For 1 to 1 Flowire connections with A/B redundancy, we recommend:

  • Leave the Flowires connected to the system switches on “Auto”
  • Set the Flowires connected to the field equipment to “Not CCo”

More information about Flowire’s CCo settings.

For more information on configuring Flowire in Exigo systems, see our Exigo Flowire Guidelines.