Actions

IP Desktop Station LED Indications

From Zenitel Wiki

Revision as of 12:51, 17 November 2020 by Roarl (talk | contribs)

Station LED

LED4 - Red 5mm LED on board rear side, also seen through front plate.

Station LED


Blinking at 1 second intervals:
Station has no connection to the ICX-AlphaCom

Possible reasons:

  • No connection to Ethernet
  • Wrong AlphaCom IP address configured
  • Invalid IP address
  • No gateway or wrong gateway to the ICX-AlphaCom

Blinking at 5 second intervals:
Station connected but NOT registered in the ICX-AlphaCom

Possible reasons:

  • Station has not been programmed in AlphaPro
  • Missing IP Station license in the ICX-AlphaCom

No blinking:

Possible reasons:

  • Station connected and registered to the ICX-AlphaCom
  • Station not powered up (if no other LEDs are active)