VSF-Fortitude8 6.0 Release Notes
From Zenitel Wiki
Contents
- 1 Release info
- 2 VSF-FORTITUDE8 6.0.3.2
- 2.1 Improvements and bug fixes
- 2.1.1 MTN-3172 Setting custom hostname now survives station reboot
- 2.1.2 MTN-3168 Bitrate setting not working for RTSP streams
- 2.1.3 MTN-3165 TCIV+ volume not properly applied after start-up/reboot
- 2.1.4 MTN-3159 Not possible to start audio stream in Milestone Device Pack 11.3.
- 2.1.5 MTN-3125 Station reboots when scanning port 5060 or 5061
- 2.1.6 MTN-3117 Configuration of "Read IP" address now available for device from an Edge Controller.
- 2.1.7 MTN-3112 Ringlists can now be saved if device is an Edge Controller
- 2.1.8 MTN-1466 Cannot save firewall settings for same port with different protocols
- 2.2 Known Issues
- 2.1 Improvements and bug fixes
- 3 VSF-FORTITUDE8 6.0.3.1
- 4 VSF-FORTITUDE8 6.0.3.0
Release info
This document provides the release notes for VSF-Fortitude8 6.0 with incremental bug fix releases. These release notes are the first release notes for VSF-Fortitude8.
Name: VSF-Fortitude8
Description: VSF-Fortitude8 is a firmware for Turbine Video Plus Intercom including the following devices:
TCIV-2+, TCIV-3+, TCIV-5+, TCIV-6+ and TKIV+
The firmware is delivered in two different .swu files:
- vsff8-6.0.3.x - Used for standard in-field upgrades
- vsff8-prod-6.0.3.x - Used in production- and recovery upgrades.
Version: 6.0.3.2
Date: 12.01.2021
Status: General Availability
Compatibility: Turbine Video Plus intercom is compatible with Edge, SIP, ICX and AlphaCom systems.
VSF-FORTITUDE8 6.0.3.2
Improvements and bug fixes
MTN-3172 Setting custom hostname now survives station reboot
If hostname was modified, it would revert back to the default hostname after reboot. This is now fixed.
MTN-3168 Bitrate setting not working for RTSP streams
Bitrate setting was not properly applied to RTSP streams, both for regular and ONVIF configurations. This is now fixed.
MTN-3165 TCIV+ volume not properly applied after start-up/reboot
At start-up the main speaker volume was set to a low gain level (close config level 3) when a higher gain was configured. Any later gain change would set correct speaker gain. This is fixed, the set speaker gain will be applied after start-up as well.
MTN-3159 Not possible to start audio stream in Milestone Device Pack 11.3.
It was not possible to start audio stream if Device Pack 11.3 was installed due to wrong ONVIF audio encoder settings, the settings are now corrected.
MTN-3125 Station reboots when scanning port 5060 or 5061
Scanning SIP TCP port 5060 or SIPS TCP port 5061 would crash and reboot the TCIV+. This issue has been fixed.
MTN-3117 Configuration of "Read IP" address now available for device from an Edge Controller.
MTN-3112 Ringlists can now be saved if device is an Edge Controller
If device was an Edge Controller, the ringlist could not be saved. This has now been fixed.
Note, the ringlist worked fine if a different device was used as Edge Controller e.g. TCIS.
MTN-1466 Cannot save firewall settings for same port with different protocols
It was not possible to save firewall settings if rules with the same port number but different protocols (for example port 5060 which has rules for tcp and udp) were edited. This is now fixed.
Known Issues
MTN-3065 Sound Detection is reporting DAK-key ON twice
When Sound Detection (supported in ICX-AlphaCom mode) is enabled and sound is detected, the station emulates the push of a DAK key. In this version it reports that the DAK key is pressed twice, and released once.
SUN-476 HTTP MJPEG stream has color distortions when viewed in LenelS2 OnGuard
HTTP MJPEG stream has color distortions when viewed in LenelS2 OnGuard, recommendation is to use RTSP H.264 for video integration instead.
SUN-349 MJPEG stream shows green image in Avigilon
MJPEG stream shows green image in Avigilon, recommendation is to use H.264 for video integration instead.
VSF-FORTITUDE8 6.0.3.1
Improvements and bug fixes
MTN-3124 Station might stop working
If an internal recovery mechanism is triggered, the station is blocked from rebooting. Hence the station will stop to work. A power reboot is needed to get it working again. This issue is now fixed.
VSF-FORTITUDE8 6.0.3.0
New Features
SUN-412 TCIV+ released
This document provides the release notes for the TCIV+ Video Intercom stations which are now available.
You will find more details about the products on https://www.zenitel.com/
SUN-595 TKIV+ released as available on request item
This document provides the release notes for the TKIV+ Video Intercom kit which is available as an on-request item.
You will find more details about the product on https://www.zenitel.com/