Door Opening - Configuration example
From Zenitel Wiki
Operator 120 in conversation with Door 106, pressing digit "6" to open the door |
This article explains how to configure the Door Opening feature.
Door opening is a standard feature in the ICX-AlphaCom and AlphaCom XE. When an operator is in a conversation with a door station, the operator can press digit 6 to activate a relay. The relay will be pulsed for 3.5 seconds (configurable).
As an option, it is also possible to play a prerecorded message at the door, saying e.g. "The door is open, please enter".
Map the relay to a Logical RCO
All Zenitel IP stations have an inbuilt relay. The relay must be mapped to a "Logical RCO" in the ICX-AlphaCom server. The mapping is done from AlphaPro, Exchange & System > RCO. Here the logical RCO is assigned to a physical address. The physical address is given as Station ID + Pin Number.
Open Exchange & System > RCO, and select a free RCO from the list to the left and click the Change button:
Setting the Edge Controller |
Change the following parameters:
- Description: Any text
- RCO Type = Station
- Station physical number: The physical number of the door station (Not the directory number)
- Pin number: The output number related to the relay, normally "7" (see below)
Setting the Edge Controller |
What Pin Number to use depends on the station type:
- Zenitel IP Stations (Turbine generation): Use Pin Number = 7
- INCA Stations (the old generation Zenitel IP stations): Use Pin Number = 1
For an overview of which devices are supporting RCOs and what pin numbers they use, see Devices_supporting_RCOs
Event Handler
We need to define who this event is for, and which output to activate. This is done using the Event Handler. Go to Exchange & System menu from the top menu in AlphaPro:
From the Exchange & System window choose the Events button:
In the Event Actions window click the Insert button and create an event like this:
This event is triggered when the operator dials digit 6 while in conversation with the door. Note that the Door Station is the owner of the event (here physical number 6). When Related To can be set to "All", meaning whoever in conversation with the door is allowed to dial digit 6 to open the door. In this example we have chosen to limit this access by selecting a single station; Operator with Directory number 120.
In the example above RCO 6 will be triggered when the Door Opening feature (digit 6) is pressed.
Finalization
Close all windows in AlphaPro and upload the database using the Send All button. Apply changes by restarting the server.