VSF-Fortitude8 7.3 Release Notes
From Zenitel Wiki
- Previous Release - VSF-Fortitude8 7.2 Release Notes
- Next Release - VSF-Fortitude8 7.4 Release Notes
This document provides the release notes for VSF-Fortitude8 7.3 with incremental bug fix releases. The release notes for VSF-Fortitude8 7.3 describe new features, improvements and issues fixed after VSF-Fortitude8 7.2.
Contents
- 1 Release info
- 2 VSF-FORTITUDE8 7.3.3.1
- 3 VSF-FORTITUDE8 7.3.3.0
- 3.1 Issues fixed
- 3.1.1 MTN-3922 Intercom set to correct device type after software upgrade
- 3.1.2 MTN-3918 AVC - Default value for Far-end Lockout Time changed to 100 ms. Debug in Display now shows 0 dB
- 3.1.3 MTN-3905 Triggering relay via ONVIF in ICX-AlphaCom mode fixed
- 3.1.4 MTN-3882 Fixed DAK function for Volume Control
- 3.1.5 MTN-3860 ONVIF issue with AMAG Symmetry fixed
- 3.2 Known Issues
- 3.1 Issues fixed
Release info
Name: VSF-Fortitude8
Description: VSF-Fortitude8 is a firmware for Turbine Plus Intercoms including the following devices:
TCIV-2+, TCIV-3+, TCIV-5+, TCIV-6+, TKIV+ and TMIV-1+
The firmware is delivered in two different files:
- vsff8-7.3.3.x - Used for standard in-field upgrades
- vsff8-prod-7.3.3.x - Used in production- and recovery upgrades.
Version: 7.3.3.1
Date: 25.11.2022
Status: General Availability
VSF-FORTITUDE8 7.3.3.1
Issues fixed
MTN-3972 It is now possible to upgrade new products with hardware revision 4 to software vsff8-7.3.3.1 or higher
Hardware revision 4 can not be upgraded to vsff8-7.3.3.0
Known Issues
SUN-476 HTTP MJPEG stream has color distortions when viewed in LenelS2 OnGuard
HTTP MJPEG stream has color distortions when viewed in LenelS2 OnGuard, recommendation is to use RTSP H.264 for video integration instead.
SUN-349 MJPEG stream shows green image in Avigilon
MJPEG stream shows green image in Avigilon, recommendation is to use H.264 for video integration instead.
VSF-FORTITUDE8 7.3.3.0
Issues fixed
MTN-3922 Intercom set to correct device type after software upgrade
Fixed an issue where intercom would be set as a kit after the upgrade.
MTN-3918 AVC - Default value for Far-end Lockout Time changed to 100 ms. Debug in Display now shows 0 dB
Default value for AVC parameter Far-end Lockout Time was set to 1 second. This is now changed to 100 milliseconds. Also, Debug in Display wouldn't show correct value for no gain raise, i.e. 0 dBA raise, this is now fixed, and correct 0 dB value is shown.
MTN-3905 Triggering relay via ONVIF in ICX-AlphaCom mode fixed
Fixed an issue which prevented relay being triggered over ONVIF if station is in ICX-AlphaCom mode
MTN-3882 Fixed DAK function for Volume Control
When DAK function is set to Volume Control, pressing DAK wouldn't raise or lower the gain. This is now fixed, and volume can be configured also with DAK.
MTN-3860 ONVIF issue with AMAG Symmetry fixed
Fixed an issue which prevented station from being added to AMAG Symmetry.
Known Issues
SUN-476 HTTP MJPEG stream has color distortions when viewed in LenelS2 OnGuard
HTTP MJPEG stream has color distortions when viewed in LenelS2 OnGuard, recommendation is to use RTSP H.264 for video integration instead.
SUN-349 MJPEG stream shows green image in Avigilon
MJPEG stream shows green image in Avigilon, recommendation is to use H.264 for video integration instead.