Installation
VR3G-1 can be powered by PoE. This is done by connecting an Ethernet cable to the LAN port of the station and a PoE switch.
If PoE is used, the station must be installed using a shielded Ethernet cable with grounding at the switch end |
If the switch does not support PoE, a 24VDC power supply can be connected to the stations Power Input.
Mounting
Mounting considerations
Check the specification of the product for the installation environment.
To ensure the IP66 rating and that nothing can penetrate behind the edge of the intercom, it must be mounted on a surface that is completely planar. |
Flush mounting
When flush mounting vandal resistant station, use the 3 Gang Flush Mount back box.
- Ready one of the pre-punched holes in the backbox for power and network wiring.
- Have the necessary cables ready before starting the mounting procedure
- Insert and secure the 3 Gang Flush Mount back box into designated slot in the wall. Make sure that the box is squarely mounted and the front surface flush with the wall surface.
- Plug the Ethernet cable into LAN port on the station. If the switch does not support PoE, a 24VDC Power Supply can be connected to the stations Power Input.
- Mount the Vandal Resistant Station onto the back box with the 6-32 UNC X ¾ fasteners provided. Apply 1.5 Nm / 1.1 lb-ft torque.
Dimensions
VR3G-1
- Dimensions (HxWxD): 160x114x60mm
- Dimensions after flush mount: 160x114x5mm
VR3G-1P
- Dimensions (HxWxD): 160x114x60mm
- Dimensions after flush mount: 160x114x4mm
- Return to Vandal Resistant intercom - VR3G-1
- Return to Vandal Resistant intercom - VR3G-1P