VSF-Fortitude6 6.2 Release Notes
From Zenitel Wiki
Previous Release - VSF-Fortitude6 6.1 Release Notes
Next Release - VSF-Fortitude6 6.4 Release Notes
This document provides the release notes for VSF-Fortitude6 6.2 with incremental bug fix releases. The release notes for VSF-Fortitude6 6.2 describe new features, improvements and issues fixed after VSF-Fortitude6 6.1.
Contents
- 1 Release info
- 2 VSF-FORTITUDE6 6.2.3.1
- 2.1 Issues fixed
- 2.1.1 MTN-3403 IP Flush Master V2 and IP-CROR in ICX-AlphaCom mode needed 3 button press to change LCD brightness
- 2.1.2 MTN-3400 LCD backlight steps on IP Flush Master V2 and IP CROR
- 2.1.3 MTN-3384 Keypad dimming has been fixed for IP Flush Master V2.
- 2.1.4 MTN-3377 Fixed behaviour of IP Desk Master V2 while Audio program is active
- 2.1.5 MTN-3255 Calls going through 3CX SBC hangs up after 30 seconds
- 2.1 Issues fixed
- 3 VSF-FORTITUDE6 6.2.3.0
- 3.1 Improvements
- 3.2 Issues fixed
- 3.2.1 MTN-3180 IP flush master now only shows 1 relay in configuration
- 3.2.2 MTN-3334 TLS 1.1. support over https is removed from devices
- 3.2.3 MTN-3343 Set time manually has been fixed for IP Desk Master V2 devices in Edge and SIP mode
- 3.2.4 MTN-3352 Issue with headset on IP Desk Master-V2 is now fixed
- 3.2.5 MTN-3355 The three inputs on the PCB of the IP Desk Master-V2 are now supported
Release info
Name: VSF-Fortitude6
Description: VSF-Fortitude6 is a firmware for Zenitel devices based on the IMX6 processor.
The firmware is delivered in two different files:
- vsff6-6.2.3.x - Used for standard in-field upgrades
- vsff6-prod-6.2.3.x - Used in production- and recovery upgrades.
Version: 6.2.3.1
Date: 09.08.2021
Status: General Availability
Compatibility: IP Desk Master V2 and IP Flush Master V2 and IP-CROR are compatible with Edge, SIP, ICX and AlphaCom systems.
VSF-FORTITUDE6 6.2.3.1
Issues fixed
MTN-3403 IP Flush Master V2 and IP-CROR in ICX-AlphaCom mode needed 3 button press to change LCD brightness
IP Flush Master V2 and CROR in ICX-AlphaCom mode needed 3 button press to change LCD brightness, it now needs only one press.
MTN-3400 LCD backlight steps on IP Flush Master V2 and IP CROR
LCD backlight steps have been changed for IP Flush Master V2 and IP-CROR, minimum brightness is now lower than before
MTN-3384 Keypad dimming has been fixed for IP Flush Master V2.
MTN-3377 Fixed behaviour of IP Desk Master V2 while Audio program is active
When handset of IP Desk Master V2 was offhook when alarm started to play, and handset is put back in cradle, dial tone would start playing on loudspeaker. This is now fixed, so alarm is played on loudspeaker. Further, when handset was onhook when alarm started, and then raised, dial tone would start to play on loudspeaker. This is now fixed, so both alarm and dial tone/conversation can be heard in the handset.
MTN-3255 Calls going through 3CX SBC hangs up after 30 seconds
The record-route handling for strict routing did not work properly. This is now fixed.
VSF-FORTITUDE6 6.2.3.0
Improvements
RED-46 IPv6 is supported in SIP mode
If IP address of the ICX-AlphaCom server was configured, but not connected to ICX-AlphaCom server, IP address 0.0.0.0 would show in device info on the device itself. This is now fixed. The IP of the ICX-AlphaCom server is displayed on the device even if it has lost connection to the ICX-AlphaCom server.
Issues fixed
MTN-3180 IP flush master now only shows 1 relay in configuration
Before there was incorrect option to select up to 3 relays but it is only 1 relay that is actually existing on device.
MTN-3334 TLS 1.1. support over https is removed from devices
MTN-3343 Set time manually has been fixed for IP Desk Master V2 devices in Edge and SIP mode
MTN-3352 Issue with headset on IP Desk Master-V2 is now fixed
If headset on the IP Desk Master-V2 was used, the headset would not be detected after use of the handset. This is now fixed.
MTN-3355 The three inputs on the PCB of the IP Desk Master-V2 are now supported