Release info

Name: VSF-Fortitude6
Description: VSF-Fortitude6 is a firmware for Zenitel devices based on the IMX6 processor.

The firmware is delivered in two different files:

  • vsff6-9.0.3.x - Used for standard in-field upgrades
  • vsff6-prod-9.0.3.x - Used in production- and recovery upgrades.

Version: 9.0.3.0
Date: 03.10.2024
Status: General Availability


VSF-FORTITUDE6 9.0.3.0

Improvements

DS-899 SIP/SDP support for dynamic payload for codec L16x48 (HD-Audio)

Now supporting SIP media attribute L16/48000 with dynamic payload type in range 96..127. Note! The device needs to be configured in “HD-Audio” mode and voice processing (AEC and NC) is not supported.


Fixed Issues

MTN-4435 RTSP stream could stop in some cases

In case of audio issues, RTSP stream would terminate. Now the stream will continue with a moment of silence instead.

MTN-4394 Multicast paging working again on intercom devices

Multicast paging was not working on intercom devices when configuring from the webpage. This is now fixed.

MTN-4362 Fixed wrong description in Sound Detection settings

The description of “Minimum time before reactivation” is corrected to “Choose how long to wait before enabling VAD after triggering the DAK key”

MTN-4340 ONVIF backchannel could cut last second of audio

In some cases backchannel could cut around last second of audio when using push to talk or pre-recorded messages that terminate backchannel session.

This does not happen anymore if client sends TEARDOWN command correctly.

MTN-4329 Fixed an issue with wrong intervals for ONVIF events reports

Fixed an issue with wrong parsing of some PullMessages parameters. In some VMSs, PullMessages parameters Timeout and MessageLimit were not parsed correctly on VS-IS8.0.3.2 and wrong values were used.

MTN-4320 Weak cipher suites no longer supported on devices

Removed the AES128-SHA AES128-SHA256:ECDHE-RSA-AES128-SHA:ECDHE-RSA-AES256-SHA:CAMELLIA128-SHA:CAMELLIA256-SHA ciphers reported by security scanner

MTN-4246 Fixed an issue with input status on CRM-V2 that was lost after ICX-AlphaCom restart

After ICX-AlphaCom was restarted the input status of the CRM-V2 was lost. This is now fixed.

MTN-4228 Turbine devices could not be used with Bosch VMS

There was a problem on Zenitel ONVIF devices that caused software to crash and device to reboot which made Bosch VMS unable to connect to the device.