Siemens SiPass - ICX-AlphaCom integration
From Zenitel Wiki
Contents
Introduction
Description
The integration between SiPass and the AlphaCom is OPC based.
The article describes how to interface SiPass integrated with the Zenitel stations in order to get the Alarms and Events via OPC.
Applications:
- Hotels and Resorts
- Casinos
- Military establishments
- Police forces
- Fire brigades
- Prisons
- Hospitals
- Banks and Financial Institutions
- Industries
Licensing
ICX
ICX requires the presence of the appropriate API/OPC license. With ICX it is possible to purchase a single Product Key which covers all stations connected to all ICX's in a network. ICX licenses can be stacked, i.e. 1x 1002602306 + 2x 1002602309 gives 1088 API licenses which can be used on 2 or more ICXs.
- 1002602306 - ILI-API64 - API License Supporting 64 Stations
- 1002602309 - ILI-API512 - API License Supporting 512 Stations
AlphaCom
The AlphaCom requires the presence of the appropriate API/OPC license. Note that every AlphaCom in an AlphaNet requires such a license.
- 1009649901 - STENTOFON API License Supporting 40 Stations
- 1009649902 - STENTOFON API License Supporting 80 Stations
- 1009649903 - STENTOFON API License Supporting 160 Stations
- 1009649904 - STENTOFON API License Supporting 240 Stations
- 1009649905 - STENTOFON API License Supporting 320 Stations
- 1009649906 - STENTOFON API License Supporting 400 Stations
- 1009649907 - STENTOFON API License Supporting 552 Stations
OPC Server Configuration
Follow the installation instructions for OPC Classic for AlphaCom - Installation
An example configuration could look like this