Start Alarm message at station feature
From Zenitel Wiki
| Feature: | Alarm Message to Station |
| Default directory number: | 8900 - 8909 |
| Feature number: | 67 |
| Parameter 1: | 0 (N/A) |
| Description: | Reset status indicator LED in front of AlphaCom E20 and AlphaCom E26. |
67 FEAT_ALARM_MSG
| Param1 | Description |
|---|---|
| ?? | Start alarm message at station |
| Play alarm message on own station.
Message is supplied from ASVP board. Message no 0 = OFF. Message no range is 1-9. | |