Status LED
From Zenitel Wiki
The status LED indicator is located in front of the AlphaCom E20 and AlphaCom E26 cabinet. The status LED is steady green when all is in order. An error situation is indicated by flashing red light:
- System startup: Red -> Amber -> Green light
- Board error: Red light. The AMC-IP board can no longer find one or more boards in the exchange. Could be due to a faulty board, or that a board has been moved to another position or removed. A board error in a slave module in a MultiModule system is reported on the LED of the master module, the LED in slave module will not indicate board error.
- MultiModule communication error:
- Master module: Red light if the master module has lost contact with the slave(s)
- Slave module(s): If a slave has lost contact with the master module, the LED in the slave will light steady amber while the slave is rebooting, then the LED goes green when the module has come up in autonomy mode
- Remote Control Input (RCI): Red light when the RCI is active. Requires software configuration from AlphaPro. In Exchange & System > RCI, set the flag "Activate Faulty Module LED".
The exchnage status and status indicator LED can be reset by dialling the code 7871.