OPC Server - Release Notes
From Zenitel Wiki
Release State: Released
Release Version: 5.0.0.0
Installation Package: OPCServerSetup.msi
Contents
AlphaCom OPC Server 5.0.0.0 (2009-07-01)
Functional Changes/Enhancements
Major changes
- Re-written to use the new Stentofon.AlphaCom.AlphaNet.dll library.
- Config file name and format is changed with the new library. New config file name: Stentofon.AlphaCom.AlphaNet.OPC.xml
The OPCServerConfigurator application will test for old config file, and prompt for automatic conversion to the new format. - Implemented Redundant OPC Server mode allowing two OPC Devices connect to the same AlphaCom nodes. Requires AlphaCom Sys version 10.55
- The station item .relatedto is now updated on AlphaCom CallStatus event. The .relatedto property will then be set on calls in private mode, before the call is accepted.
<br\> Easy Projects Activities
Activity | Short Description |
---|---|
209 | Make (IP) station IO items based on ST_STATE messages, make RCO/RCI item obsolete |
210 | Make global node RCI based on RCI_CHANGED messages incl OPC/RCI config |
211 | Implemented OPC Items for M-Key, C-Key and DAK-key |
217 | Updated to use library Stentofon.AlphaCom.AlphaNet.dll |
166 | Redundant OPC Server |
Limitations
Global RCI/RCO states is updated on state changes, but is not synchronized at OPC Server startup.
Errors Corrected
Easy Projects Activities
Activity | Short Description |
---|---|
205 | cr_iterate_command items offset |
206 | OPC AE: "Station UP" is reported on all ST_STATE changes |
AlphaCom OPC Server 4.1.0.0 (2009-04-01)
Functional Changes/Enhancements
Added the OPC AE event StationSignal (.signal).
This event is generated from the station sending a Call Request ("I need attention")
AlphaCom OPC Server 4.0.0.0 (2008-10-29)
First official Release