Actions

AudioCodes MP114/118, v5.4 and higher

From Zenitel Wiki

Revision as of 15:23, 13 August 2009 by Hege2 (talk) (Feature Guide)

This article describes the setup of the AlphaCom E system and the AudioCodes MP-114/118 SIP Gateway, firmware version 5.4 and 5.6. The article covers the most common features used in an AlphaCom ↔ AudioCodes interconnection.

AlphaCom-Configuration.jpg

The configuration of AlphaCom E with SIP gateway includes the following steps:

Using AlphaWeb

  • Assign IP address to the AlphaCom Ethernet port
  • Insert SIP Trunk licenses
  • Firewall (filter) settings

Using AlphaPro

  • Create a SIP Trunk Node
  • Define the AlphaCom / SIP routing
  • Create prefix numbers
  • Update the exchange

AlphaCom Configurations

AlphaWeb Configurations

Assign IP adress to the AlphaCom E Ethernet port(s)

  • Log on to AlphaWeb and enter a valid IP address on the Ethernet port.

In the example below, Ethernet port 1 is used. Consult your network administrator to obtain the IP address.

Assign IP address to the AlphaCom E Ethernet.jpg

Insert SIP Trunk licenses

Log on to AlphaWeb and install the SIP Trunk license.

Insert SIP Trunk licenses.jpg

Firewall (filter) settings

Enable the SIP protocol and VoIP Audio on the desired Ethernet port (default enabled for Ethernet port1).

Firewall (filter) settings.jpg

AlphaPro Configuration

Create a SIP Trunk Node

From the AlphaPro main menu, use the ‘+’ button next to the ‘Select Exchange’ dropdown list to create a new exchange. The exchange type must be set to ‘SIP Node’.

Set the parameters as follows:

Create a SIP Trunk Node.jpg

The SIP Trunk IP address must be identical to the IP address of the SIP Gateway.

Note: If the AlphaCom is configured with a SIP Registrar node in addition to the SIP Trunk node, the SIP Registrar node must have a lower node number than the SIP Trunk node.

Define the AlphaCom / SIP routing

In Exchange & System > Net Routing use the Insert button to create a route between the AlphaCom and SIP Gateway. Set Preferred codec to G711u and RTP Packet Size to 20 ms.

Define the AlphaCom , SIP routing.jpg

Create Prefix number

The directory number (prefix) used to access the telephone line must be programmed in the AlphaCom directory table with feature 83 and Node = SIP Trunk node number (100 in this example). In the example below the default directory number 0 has been modified to be used as a prefix.

Create Prefix number.jpg

Update the exchange

Log on to the exchange and update the exchange by pressing the SendAll button. Reset the exchange after the send operation is finished.

Audiocodes MP-114/118 Configuration

Configure Network Parameters

Configure Network Parameters 1.jpg
Configure Network Parameters 2.jpg

The AudioCodes MP-114/118 VoIP Gateway comes with default network parameters (factory default parameters).

Before you can set up the gateway in the network, you have to change the default IP address to a fixed IP address in your network environment. The unit is configured from a web browser, e.g. Internet Explorer or Navigator. Consult the network administrator to get the correct IP address.

Follow these steps:

  • Load factory network parameters and reset the username and password to its default settings (username: Admin, password: Admin) by following these three steps:

1. Disconnect the Ethernet cable from the device.
2. With a paper clip or any other similar pointed object, press and hold down the Reset button (located on the rear panel) for about six seconds; the Fail LED turns red and the device restores to factory default settings.
3. When the Fail LED turns off, reconnect the Ethernet cable to the device.

  • The VoIP Gateway will now get the IP address 10.1.10.11, subnet mask 255.255.0.0.

Change the IP address of your PC to 10.1.10.12, subnet mask 255.255.0.0.

Connect the LAN port of the PC to the Ethernet port of the Gateway. Use a crossed cable or connect the PC and the VoIP Gateway to a common switch using straight cables.

  • Start your Web Browser and type 10.1.10.11 in the URL field.
  • Type in user name Admin and password Admin. (Case-sensitive!)

The Home page of the Web Interface:

Configure Network Parameters 3.jpg

IP Configuration

  • In the 'IP Settings' page (Configuration tab > Network Settings menu > IP Settings page item) enter the IP Address, Subnet Mask and optionally the Default Gateway Address of the AudioCodes Gateway.

This IP address must be identical to the IP address of the SIP Trunk Node created in AlphaPro.

  • Click Submit to apply the changes.

IP Configuration.jpg

Note: The IP address is immediately changed when pressing Submit, but it is not permanently stored. Without resetting or powering off the device, you need to log on to the Gateway using its new IP address in order to Burn the new IP address to flash:

  • Disconnect the PC from the Gateway.
  • Reconnect the Gateway and PC to the LAN. The PC and Gateway must be on the same sub-net.
  • Restore the PC’s IP address and subnet mask to what they originally were, and re-access the Gateway using the new assigned IP address.
  • Click Burn to permanently apply the changes.

SIP Parameters

  • In the 'Proxy & Registration' page (Configuration tab > Protocol Configuration menu > Protocol Definition submenu > Proxy & Registration page item) set the ‘Use Default Proxy’ field to ‘Yes’.
  • Click the Proxy Set Table button. In the ‘Proxy Address’ field enter the IP address of the AlphaCom.
  • Set 'Transport Type' to 'UDP'.

SIP Parameters.jpg

  • Press Submit to save changes

Audio Codec

  • Select the voice coder in 'Coders Table' page (Configuration tab > Protocol Configuration menu > Protocol Definition submenu > Coders page item). Choose G.711U-law Coder Name, 20 ms Packetization Time and Silence Suppression Disabled.

Audio Codec.jpg

  • Press Submit to save changes

About Saving Changes

The Submit button will save the data to the running volatile memory. The changes take effect on-the-fly. The changes will not survive hardware reset or power off.

To permanently save the configuration data, store the data to flash memory by selecting Burn from the Tool Bar.

Note: Parameters proceeded by a yellow lightning symbol is not changeable on-the-fly and require that the device is reset.

Backup and Restore

The configuration of the AudioCodes Gateway can be stored to a file on your PC.
From the Tool Bar select Device Actions -> Save Configuration File. Select Save INI File to save the configuration to the PC, and select Load INI File to upload a configuration file to the SIP Gateway.

AlpphaCom to Telephone Network

There are two ways of selecting a FXO line from the AlphaCom.

  • Group Hunt, where a prefix is dialed and you are connected to one out of several lines
  • Direct FXO line selection, where there is one prefix assigned for each of the FXO lines.

The two methods can be combined.


Group Hunt

Dial a prefix and get connected to a free FXO line.
Hunt Group Settings

  • In the 'Hunt Group Settings' page (Configuration tab > Protocol Configuration menu > Hunt/IP Group submenu > Hunt Group Settings page item) set the ‘Hunt Group ID’ field to ‘1’ and ‘Channel Select Mode’ to ‘Cyclic Ascending’.

Group Hunt.jpg

IP to Hunt Group Routing When dialing the prefix from AlphaCom, the call needs to be routed to the appropriate Hunt Group ID associated with the FXO ports. In the example below the call is routed to group hunt ID 1. (Configuration tab > Protocol Configuration menu > Routing Tables submenu > IP to Trunk Group Routing page item)

IP to Hunt Group Routing.jpg

Endpoint Phone Number

In the ‘Endpoint Phone Number Table’ page the FXO lines are linked to the prefix in AlphaCom and to the hunt group ID. (Configuration tab > Protocol Configuration menu > Endpoint Number submenu > EndPoint Phone Number page item).

In the example below all four FXO lines belong to Hunt Group ID 1. When dialing 0 on an intercom station the first available line will be granted. Directory number 0 must be programmed in the AlphaCom directory table with feature 83/<node>. See paragraph 2.2.3.

Endpoint Phone Number.jpg

If there are unused lines, leave the fields for that line blank.

FXO Line Select

In installations with different types of equipment connected to the various FXO lines the user must be able to select which FXO port to use. On a ship, for instance, there could be a mix of shore lines, GSM interface and Satelitte lines. Line selection is achieved by assigning each port a unique Phone Number in the Endpoint Phone Number Table. These directory numbers must be programmed in the AlphaCom directory table with feature 83/<node>. See paragraph 2.2.3.

Replace “0” with four lines, “41” to “44”.

FXO Line Select.jpg

In this table the four FXO lines are selected by dialing 41 – 44 If there are unused lines, leave all fields for that line blank. Group hunt is not used in this call mode, and the IP to Hunt Routing Table must be empty.

FXO Line Select2.jpg

Telephone Network to Alpha Com

You can choose between three different ways of handling an incoming call from the telephone line:

  • Selective Dialing
  • Automatic Dialing
  • Delayed Automatic Dialing


Selective Dialing

A second dial tone will be presented when calling in, and the user can dial the desired intercom number. The fields in the ‘Automatic Dialing’ page item must be left blank (Default setting). (Configuration tab > Protocol Configuration menu > Endpoint Settings submenu > Automatic Dialing page item).

Selective Dialing.jpg

In this mode the gateway collects digits from the line, and sets up the call towards the AlphaCom when a predefined number of digits are collected and no more digits are received within a preset time (default 4 seconds), or when the ‘#’ key is dialed.

In the 'DTMF & Dialing' page (Configuration tab > Protocol Configuration menu > Protocol Definition submenu > DTMF & Dialing page item) select ‘Advanced Parameter List’ in order to view all parameters, and set ‘Max Digits In Phone Num’ equal to the number of digits used on the AlphaCom stations, normally 3 or 4. The parameter ‘Inter Digit Timeout for Overlap Dialing’ specifies the waiting time for more digits before setting up the call.

Selective Dialing2.jpg

Automatic Dialing (Call to Switchboard)

When calling in, the call will automatically be connected to a predefined intercom number.

  • Enter the intercom number in the ‘Destination Phone Number’ field in the ‘Automatic Dialing’ page item. Set ‘Auto Dial Status’ to ‘Enable’. (Configuration tab > Protocol Configuration menu > Endpoint Settings submenu > Automatic Dialing page item).

Automatic Dialing (Call to Switchboard).jpg

In the example above, incoming calls on line 1 are routed to station 103, calls on line 2 are routed to station 101, and calls on line 3 and 4 are routed to RingingGroup 6701.

Delayed Automatic Dialing

If ‘Auto Dial Status’ is set to ‘Hotline’, a second dial tone will be presented when calling in, allowing the user to dial a number. But if no digits are pressed within the ‘Hotline Dial Tone Duration’ time, the number in the Destination Phone Number is automatically dialed.

Delayed Automatic Dialing.jpg

The ‘Hotline Dial Tone Duration’ can be changed from the 'DTMF & Dialing' page item (Configuration tab > Protocol Configuration menu > Protocol Definition submenu > DTMF & Dialing page item). Select the ‘Advanced Parameter List’. The default value is 16 seconds.

Caller ID

Use the ‘Caller Display Information’ page to send display information to the intercom station that receives the call. (Configuration tab > Protocol Configuration menu > Endpoint Settings submenu > Caller Display Information page item).

Caller ID.jpg

The prefix code entered in the End Point Phone Number Table will be shown together with the text in Caller ID/Name.

If Caller ID name is detected on the FXO line, this will be used instead of the Caller ID name in the table above. Display the Navigation Tree in Full View. Caller ID from FXO line must be enabled in Configuration tab > Protocol Configuration menu > SIP Advanced Parameters submenu > Supplementary Services page item.

  • Set ‘Enable Caller ID’ to ‘Enable’ and choose the ‘Caller ID Type’ as used by the PSTN supplier. Check with the local telephone company to find the ‘Caller ID Type’ used.

Caller ID 2.jpg

Far end disconnect (FED)

Far End Disconnect refers to methods for detecting that a remote party has hung up. The far end disconnect signal is not mandatory and this could create problems. If the Far End Disconnect signal is not sent to or properly detected by the SIP Gateway, the connection will not be released by the unit, thus freezing the FXO line in the off hook state.

Call Termination options in the SIP Gateway

The following methods for call termination are supported by the AudioCodes MP-114/118. Note that the used disconnection methods must be supported by the CO (Central Office) or to PBX (Private Branch Exchange).

  • Detection of polarity reversal / current disconnect
  • Detection of Busy / Dial tones
  • Detection of silence
  • Timeout of Conversation

Detection of polarity reversal / current disconnect

This is the recommended method. The call is immediately disconnected after polarity reversal or current disconnect is detected on the Tel side (assuming the PBX / CO produces this signal).

  • Display the Navigation Tree in Full View. Enable the relevant detection method in Configuration tab > Protocol Configuration menu > SIP Advanced Parameters submenu > Advanced Parameters page item.

Detection of polarity reversal , current disconnect.jpg

Detection of Busy / Dial tones

The call is immediately disconnected after Busy or Dial tone is detected on the Tel side (assuming the PBX / CO produces this tone). This method requires the correct tone frequencies and cadence to be defined in the Call Progress Tones (CPT) file of the SIP Gateway. If these frequencies are not known, define them in the CPT file (the tone produced by the PBX / CO must be recorded and its frequencies analyzed). This method is slightly less reliable than the previous one.

  • Open the ‘FXO Settings’ page item in Configuration tab > Advanced Applications menu > FXO Settings page item and enable the relevant detection method.

Detection of Busy , Dial tones.jpg

Call Progress Tones (CPT)
The Detection of Busy / Dial tones method requires the correct tone frequencies and cadence (on/off sequence) to be defined in the Call Progress Tones (CPT) file of the SIP gateway. These tones are region specific and telephone exchange dependent.

The Call Progress Tones (CPT) configuration file is a binary file (with the extension .dat).

Users can either use one of the supplied configuration (dat) files found on the CD provided with the gateway, or construct their own file.

A file with the most common tone patterns can also be downloaded from [www.zenitel.com/stentofon/support]
To construct your own file, either:

  • Modify the supplied usa_tone.ini file (in any standard text editor) to suit the specific requirements, and convert the modified ini file into binary format using the TrunkPack Downloadable Conversion Utility.

Or:

  • Use the Call Progress Tones Wizard.

The Call Progress Tones Wizard (CPTWizard) is an application designed to detect the Call Progress Tones generated by your PBX (or telephone exchange) to create a basic Call Progress Tones ini file containing definitions for all relevant Call Progress Tones. This provides a good starting point when configuring the SIP gateway. This ini file can then be converted to a dat file using the TrunkPack Downloadable Conversion utility.

Both the TrunkPack Downloadable Conversion Utility
(DConvert.exe) and the Call Progress Tones Wizard (CPTWizard.exe) can be found on the AudioCodes CD.

  • Load a Call Progress Tones (dat) file to the SIP gateway:
  • Select Management tab > Software Update menu > Load Auxiliary Files page item.

Call Progress Tones (CPT).jpg

  • Click the Browse button and navigate to the folder that contains the file you want to load
  • Click the file and click the Open button; the name and path of the file appear in the field beside the Browse button
  • Click the Load File button
  • Burn the configuration so the file can be available after a power failure
  • Reset the SIP Gateway for the changes to take effect

For more detailed information regarding Call Progress Tones please refer to the AudioCodes User's Manual found on the CD supplied with the unit.



Detection of Silence

The call is disconnected after silence is detected on both call directions for a specific (configurable) amount of time. This method should only be used as a backup.

  • Display the Navigation Tree in Full View. Enable the relevant detection method in Configuration tab > Protocol Configuration menu > SIP Advanced Parameters submenu > Advanced Parameters page item.

Detection of Silence.jpg

Timeout of Conversation

As an additional safety to prevent lines from accidentally locking up, it is recommended to enable a timeout of conversation.

The ‘Max Call Duration’ defines the maximum call duration in minutes. If this time expires, both sides of the call are released (IP and Tel). The valid range is 0 to 120. The default is 0 (no limitation).

  • Display the Navigation Tree in Full View. Enable the ‘Max Call Duration’ in Configuration tab > Protocol Configuration menu > SIP Advanced Parameters submenu > Advanced Parameters page item.

Timeout of Conversation.jpg

Message log

The 'Message Log' page displays Syslog debug messages sent by the device. You can select the Syslog messages in this page, and then copy and paste them into a text editor such as Notepad. This text file (txt) can then be sent to Technical Support for diagnosis and troubleshooting.

Note: It's not recommended to keep a Message Log session open for a prolonged period. This may cause the device to overload. For prolonged (and detailed) debugging, use an external Syslog server.

To activate the Message Log, take these 3 steps:

  • In the 'Advanced Parameters' (Configuration tab > Protocol Configuration menu > SIP Advanced Parameters submenu > Advanced Parameters page item), set the parameter 'Debug Level' to 6. This parameter determines the Syslog logging level in the range 0 to 6, where 6 is the highest level.
  • Open the 'Message Log' page (Status & Diagnostics tab > Status & Diagnostics menu > Message Log page item). Now the 'Message Log' page is displayed and the log is activated.

Message log.jpg

The displayed logged messages are color coded as follows:

  • Yellow - fatal error message
  • Blue - recoverable error message (i.e., non-fatal error)
  • Black - notice message
  • To clear the page of Syslog messages, in the Navigation tree, click the page item Message Log again; the page is cleared and new messages begin appearing.


To stop the Message Log, take this step:

  • Close the page by accessing any another page in the Web interface.

Miscellaneous features

Incomming Calls in Private

Incoming Calls in Private.jpg

Incoming calls from the telephone line can be forced to be in private ringing mode, independent of the private/open switch of the intercom station.

Check the flag Incoming calls from SIP in private ringing mode in AlphaPro, (Exchange & System > System > VoIP).

Door Opening Feature

During a conversation between a door station and a telephone, the telephone operator can activate the Door Opening feature in the AlphaCom by pressing digit 6.

SIP Gateway Configuration

To enable digit actions from the telephone line during conversation, set ‘1st Tx DTMF Option’ to ‘INFO(Cisco)’ in the 'DTMF & Dialing' page. (Configuration tab > Protocol Configuration menu > Protocol Definition submenu > DTMF & Dialing page item).

SIP Gateway configuraion.jpg

AlphaCom configuration

AlphaCom configuration.jpg

The Door Opening feature is programmed in the Event Handler. There are two separate events for the door opening feature, depending on who is the calling side:

  • calling from the telephone to the door
  • calling from the door to the telephone


Calling from the telephone to the door:
The Standard door opening event is used.

Calling from the door to the Telephone.jpg

Calling from the door to the telephone:

When the phone presses digit 6, the event type Event Trigger Feature (15) is reported, with the digit 6 as sub event. The calling AlphaCom station is Event Owner, and called SIP phone number and node number is Related To. The RCO pulse time is specified as an additional parameter in the RCO action string, i.e. RCO 3 ON 20 means pulse RCO 3 for 2 seconds.

M-Key Control from Telephone Network

The ‘*’ and ‘#’ buttons on the telephone can be used to control M-key function (simplex audio) ON or OFF:

  • Press the ‘*’-key briefly and the M-key is turned ON
  • Press the ‘#’-key briefly and the M-key is turned OFF

This can be useful for group call announcement from the telephone. The feature is enabled by setting 1st Tx DTMF Option to INFO(Cisco) in Protocol Management > Protocol Definition > DTMF & Dialing.

Transmit '*' and '#' from AlphaCom

The DTMF signals ‘*’ and ‘#’ will be transmitted to the line when DAK 0 (*) and DAK 1 (#) is pressed during a telephone conversation. No programming is required.

Voice Switching in Noisy Environment

If the intercom station is located in a noisy environment, it might be difficult to switch the voice direction from the telephone towards the intercom station. However, there is a setting in the AlphaCom to overcome this problem. In AlphaPro, Exchange & System > System > VoIP, set the parameter Optimized voice duplex control when conversation with SIP trunk/stations

Voice Switching in Noisy Environment.jpg

When this flag is set, the initial voice direction is forced to be from the intercom towards the telephone. When the phone operator starts to speak, the voice direction will switch towards the intercom station, regardless of the level of the audio signal from the intercom station. As soon as the phone operator stops speaking, the voice direction will switch back to the initial direction.

Make sure that the Echo Canceller is enabled in the SIP Gateway. (Configuration tab > Media Settings menu > Voice Settings page item > Echo Canceller = Enabled).

Country Settings

The Line Characteristics (AC impedance matching, hybrid balance, Tx & Rx frequency response, Tx & Rx Gains, ring detection threshold, DC characteristics) should be set according to country of origin. Some of the SIP Gateway parameters are configurable through the ini configuration file only (and not via the Web). The CountryCoefficients parameter that determines the line characteristics must be configured via the ini configuration file.

  • Procedure to modify the ini file:
  • Get the ini file from the gateway using the Embedded Web Server. From the Tool Bar select Device Actions -> Save Configuration File. Select Save INI File to save the configuration to the PC:

Country Settings.jpg

  • Open the file (e.g. in Notepad) and add anywhere in the file the line

CountryCoefficients = xx

  • where xx is the country code found below; save and close the file. The example below shows the settings for Norway (46).

Country Settings 2.jpg

  • Load the modified ini file back to the gateway (using the button Load INI File).

This method preserves the programming that already exists in the device, including special default values that were preconfigured when the unit was manufactured.


Country codes

The default value is 70 (United States).

Argentina = 0
Australia = 1
Austria = 2
Bahrain = 3
Belgium = 4
Brazil = 5
Bulgaria = 6
Canada = 7
Chile = 8
China = 9
Colombia = 10
Croatia = 11
Cyprus = 12
Czech_Republic = 13
Denmark = 14
Ecuador = 15
Egypt = 16
El Salvador = 17
Finland = 18
France = 19
Germany = 20
Greece = 21
Guam = 22
Hong_Kong = 23
Hungary = 24
Iceland = 25
India = 26
Indonesia = 27
Ireland = 28
Israel = 29
Italy = 30
Japan = 31
Jordan = 32
Kazakhstan = 33
Kuwait = 34
Latvia = 35
Lebanon = 36
Luxembourg = 37
Macao = 38
Malaysia = 39
Malta = 40
Mexico = 41
Morocco = 42
Netherlands = 43
New_Zealand = 44
Nigeria = 45
Norway = 46
Oman = 47
Pakistan = 48
Peru = 49
Philippines = 50
Poland = 51
Portugal = 52
Romania = 53
Russia = 54
Saudi_Arabia = 55
Singapore = 56
Slovakia = 57
Slovenia = 58
South_Africa = 59
South_Korea = 60
Spain = 61
Sweden = 62
Switzerland = 63
Syria = 64
Taiwan = 65
TBR21 = 66
Thailand = 67
UAE = 68
United_Kingdom = 69
UnitedStates = 70
Yemen = 71

Feature Guide

Feature Guide.jpg
  • Make a call from an intercom station: Dial prefix – wait for the dial tone – dial phone number
  • When pressing digits during connection, DTMF digits are sent (Call center etc.)
  • The DTMF signals ‘*’ and ‘#’ will be transmitted when pressing DAK 1 (*) and DAK 2 (#)
  • A complete phone number can be stored under a DAK key or a substation call button.


  • Program DAK key from station:

784 + <prefix> + <phone number> + M + DAK key
Example: 784 + 0 + 40002500 + M + DAK key

  • Program from AlphaPro:

I <prefix> P <phone number>
Example: I 0 P 40002500

Call Transfer

Feature Guide 2.jpg


  • Incoming calls from the line can be transferred to another station


During conversation, dial on the keypad:

2 + <intercom station> + 3


From a preprogrammed DAK:

D 2 I 104 M M D 3


Outgoing calls to the line can be transferred to another station
During conversation, dial on the keypad:

DAK9 + 2 + <intercom station> + 3


Option: Blind Transfer
- In AlphaPro, Directory & Features menu, modify the Inquiry feature 2 from default feature 55/0 to feature 55/1.

- During conversation, dial on the keypad:

2 + <intercom station>

In a few easy steps its possible to change the logo that is seen in the top left corner in the Audiocodes web interface. Audiocodes with stentofonlogo.JPG

  • Access the device's web interface.
  • In the URL field, append the case-sensitive suffix ‘AdminPage’ to the IP address (e.g. http://10.1.229.17/AdminPage); the 'Admin' page appears.
  • On the left panel, click 'Image Load to Device'.
  • Click the Browse button, and then navigate to the folder in which the logo image file that you want to use is located.
  • Click the Send File button; the image file uploads to the device. When loading is complete, the page is automatically refreshed and the uploaded logo image is displayed in the Web interface's title bar.
  • If you want to modify the width of the image, in the 'Logo Width' field, enter the new width (in pixels) and then click the Set Logo Width button.
  • Save the image by pressing the 'Burn' button located on the top menu bar in the mainpage.