Actions

EDO - External Data Output

From Zenitel Wiki

The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.
AI.png
Note icon Using EDO in ICX-AlphaCom requires the ILI-IF license. This license is not needed if the API license is present.


EDO (External Data Output) is a user definable ASCII HEX protocol intended for CCTV control, making customized logs etc.

EDO ports can be configured as RS232 serial ports or TCP/IP ports. Up to ten EDO ports can be defined. The EDO ports are configured from AlphaPro: Exchange & System -> Serial Ports.

EDO is controlled from the Event Handler where it can be configured to send free text merged with parameters for the active stations.

Syntax

EDO "free text"                      - sends free text on the EDO port 1
EDO 1 "free text"                    - sends free text on the EDO port 1
EDO 2 "Door A2 open\x0D\x0A"         - sends Door A2 open including CR + LF on the EDO port 2
EDO 3 "Door A2 opened by %1.dir\r\n" - sends Door A2 opened by 101 including CR + LF on the EDO port 3 when 
                                       station 101 presses "6" and activates the door opening event
EDO 4 "\x02free text\x03"            - sends <STX> + free text + <ETX> on the EDO port 4 
                                       (STX = ASCII hex 02 and ETX = ASCII hex 03)


The data protocol message $PUT can also be used to output data on EDO ports:

$PUT 3 "free text"  - sends free text on the EDO port 1
$PUT 4 "free text"  - sends free text on the EDO port 2
$PUT 5 "free text"  - sends free text on the EDO port 3
$PUT 6 "free text"  - sends free text on the EDO port 4


The $PUT command is useful when the EDO data should be routed in AlphaNet:

@2 $PUT 5 "my text"  - sends my text on EDO port 3 in node 2
Note icon Note that there is an offset of two between $PUT and EDO: $PUT 4 sends to EDO port 2