Actions

Difference between revisions of "2-2a. Call indication - Event Handler (practice)"

From Zenitel Wiki

(Exercise)
 
(8 intermediate revisions by the same user not shown)
Line 1: Line 1:
[[File:1-4h config.PNG|left|thumb|450px|System configuration]]
+
[[File:2-2a exercise.PNG|left|thumb|500px|System configuration]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 
=== Exercise ===
 
=== Exercise ===
'''Door Opening'''
+
'''Call indication'''
* The call button of the Entrance should call the Reception
+
*When calling the Control Room a lamp (RCO 4) at the control room should be activated when the private ringing starts. (The Control Room is in “Private” mode).
* Pressing digit 6 at the Reception during the conversation should activate the door magnet at Entrance (RCO 1). Other stations are allowed to call to the Entrance, but not open the door.
+
*The lamp should be turned off when the private ringing stops.
* The door magnet should be active for 2 seconds
 
  
'''Code Lock (9531)'''
+
 
* The station "T. Edison" is located next to the door. By dialing a access code on the station, the associated door magnet (RCO 2) should be activated
+
'''Call indication, modified'''
 +
*The customer changes his mind; the lamp should go on when the private ringing starts and stay on also during the conversation. When the conversation ends the lamp should be switched off. If the call is not answered, the relay must drop when the ringing times out. The lamp should not go on when the Control Room makes an outgoing call, only when receiving a call.
  
 
<br><br><br><br>
 
<br><br><br><br>

Latest revision as of 16:08, 19 November 2013

System configuration


Exercise

Call indication

  • When calling the Control Room a lamp (RCO 4) at the control room should be activated when the private ringing starts. (The Control Room is in “Private” mode).
  • The lamp should be turned off when the private ringing stops.


Call indication, modified

  • The customer changes his mind; the lamp should go on when the private ringing starts and stay on also during the conversation. When the conversation ends the lamp should be switched off. If the call is not answered, the relay must drop when the ringing times out. The lamp should not go on when the Control Room makes an outgoing call, only when receiving a call.






Related articles