Actions

AMC-IP Board - Replacement procedure

From Zenitel Wiki

Revision as of 09:39, 19 September 2019 by Roarl (talk | contribs)

This article gives a short overview when it comes to replacing an AMC-IP board.

AMC-IP Board STIC position.png


Turn off power to the exchange using the main power switch located on the back of the exchange (top left corner). Remove the faulty AMC-IP board from card position 25. Remove the STIC �(STENTOFON Identity Card). Insert the STIC in the new AMC-IP board. Insert the new AMC-IP board in card �position 25. Switch on power using the main switch �on the back. Connect a computer to the exchange and open a web browser. Log on to the exchange by typing in the IP address of the exchange in the address field. Log in with the default credentials admin/alphaadmin Navigate to System Management  System Upgrade Use the “Browse” option under Upload File to select the backup file for the relevant exchange. Click Upload. Two files will now be available: System-config-backup-01.01.apkg Exchange-db-backup-01.01.1pkg Select the first file by clicking it. Click the ”Install” button that becomes available. After installation repeat for the second file. Go to System Maintenance  Backup, select “Restore DB” The system now restores the AlphaPro Database. Go to System Configuration  Interfaces and press Save followed by Apply confirm with Yes. Go to System Maintenance  System Recovery  Reboot and reboot the system All configuration and settings are now restored