The customer data '''MUST''' be backed up by doing a '''[[Communicate_(alphaPro)|GetAll]]''' operation from [[AlphaPro]] before the upgrade is performed. | The customer data '''MUST''' be backed up by doing a '''[[Communicate_(alphaPro)|GetAll]]''' operation from [[AlphaPro]] before the upgrade is performed. |
Revision as of 14:56, 8 December 2015
This article describes how to upgrade the software on a black AMC-IP board (hardware revision 5 or later).
This is the currently produced AMC-IP board. It replaced the red AMC-IP board (hardware revision 4) in 2010.
The software 11.5.3.1 is supported only on the black AMC IP boards. The red AMC-IP board is not supported.
Backup customer data
Configuration data might get lost after the upgrade.
The customer data MUST be backed up by doing a GetAll operation from AlphaPro before the upgrade is performed.
Upgrading to AMC-IP software version 11.5.3.1
Download the file bsp_31.00.3.2.apkg. This file contains the AMC-IP software version 11.5.3.1, as well as updated Linux version and security updates.
- Use an internet browser and log on to the AlphaCom Web interface (AlphaWeb) and select System Maintenance -> System Upgrade.
- Browse to the downloaded bsp file, and select Upload. The file will now be transferred from the PC to the AMC-IP board.
- When the upload is finished an Install button will appear. Press the Install button, the upgrade status is shown in the web browser.
- When the software installation is finished the system will restart with the new software.
Restore customer data
Restore the customer data by doing a SendAll operation from AlphaPro. Reset the exchange when the SendAll is finished.