'''WARNING''': This 100 9703 000 power supply is incompatible with the older 100 9701 000 supply. Do not put power supplies of different types into the same exchange module.
 
'''WARNING''': This 100 9703 000 power supply is incompatible with the older 100 9701 000 supply. Do not put power supplies of different types into the same exchange module.
 +
 +
==Mounting==
 +
* Remove the upper front cover
 +
* Remove the back covers
 +
* Slide the power supply into the rails in the upper compartment from the front side
 +
* Leave the power unit front flush with the exchangecabinet front

Revision as of 23:16, 26 November 2007

Features

AlphaCom power supply 100 9703 000
  • Made for AlphaCom 80+, AlphaCom 138, AlphaCom E20 and AlphaCom E26
  • Provides +5 V, +15 V, +24 V, and +32 V
  • Universal voltage input range from 90 to 270 VAC
  • Each power supply serves 102 standard stations
  • Can be connected in parallel for load sharing and redundancy
  • Potential-free alarm output to warn of power failure
  • The power supply shuts down if one voltage fails for protection against overheating
  • Power factor correction for efficient energy use
  • Over voltage and short circuit protected
  • Plug connector for DC outputs - no screws
  • International safety approvals
  • LED indicator per output voltage and fault
  • Built-in cooling fan

Description

The APWR power supply has four DC outputs delivering the desired voltages for AlphaCom and AlphaCom E exchanges. The power supply is able to supply a STENTOFON AlphaCom exchange equipped with maximum 17 ASLT subscriber cards, which is a fully equipped AlphaCom E20 module. In an AlphaCom E26 exchange, two power supplies are required to supply the complete module; a third can be installed for redundancy.

The power supply is easy to install and connect due to the use of Universal AMP Mate’nLock type output connectors.

WARNING: This 100 9703 000 power supply is incompatible with the older 100 9701 000 supply. Do not put power supplies of different types into the same exchange module.

Mounting

  • Remove the upper front cover
  • Remove the back covers
  • Slide the power supply into the rails in the upper compartment from the front side
  • Leave the power unit front flush with the exchangecabinet front