Actions

Difference between revisions of "AUDIO CH TONE REQ"

From Zenitel Wiki

Line 17: Line 17:
  
 
[[AlphaNet_Data_Protocol#AlphaNet|Back to AlphaNet message list]]
 
[[AlphaNet_Data_Protocol#AlphaNet|Back to AlphaNet message list]]
 +
 +
[[Category: ACDP messages]]

Revision as of 22:55, 17 December 2007

AUDIO_CH_TONE_REQ 0x8015 32789 AMC 07.00
AlphaNet: Request a peer exchange to put a 500Hz tone on a audio channel. Used by the AGA input level adjustment function. The tone stays active for 3 minutes, or until switched off using AUDIO_CH_DISCON.<br\>- Application: Send test tones for mux setup testing. Assume nodes 1 and 2, testing channel 4 in that link.

In node 1, set up two Event Trigger feature dir.nos, and assign actions in Event Handler: <br\>Send tone from node 1: <2 $audio_ch_tone_req 4 <br\>Send tone from node 2: @2 $audio_ch_tone_req 4

1 UINT1 Chanel number.


Back to AlphaNet message list