Actions

Avaya-Nortel CS1000 v. 7.6

From Zenitel Wiki

Revision as of 14:22, 17 December 2013 by Roarl (talk) (Created page with "right|thumb This article describes how to configure Avaya Communication Server 1000E R7.6 to interoperate with Zenitel Stentofon Turbine Intercom using SIP ...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Avaya 1.png

This article describes how to configure Avaya Communication Server 1000E R7.6 to interoperate with Zenitel Stentofon Turbine Intercom using SIP Line Gateway- Issue 0.1

Introduction

The article describe the configuration steps required for Zenitel Stentofon Turbine Intercom to interoperate with Avaya Communication Server 1000E R7.6 using SIP Line Gateway (SLG). The Zenitel Stentofon Turbine Intercom is a door communicator that supports voice transmission using the Session Initiation Protocol (SIP), in addition to being a door entry device. In the compliance testing, the Zenitel Stentofon Turbine Intercom was set up as a 3rd Party SIP Extension on Avaya Communication Server 1000E and underwent testing of various call scenarios with other Avaya telephones and Zenitel Stentofon Turbine Intercom units.

Configuration example

The illustrated configuration is an example for interoperability of Stentofon with CS 1000E. The CS1000E R7.6 runs on the Common Processor Pentium Mobile (CPPM) server as a co-resident configuration. The SLG application on the signaling server co-resides on the CPPM. Element Manager is used to access the SLG which resides on the Unified Communication Management Server which is accessed through the System Manager. SIP and Unistim Avaya 1140 IP Deskphones were configured. Stentofon Turbine is registered to the SLG as a Third Party SIP Client (SIP3). An ISDN-PRI trunk connects the CS1000E to the PSTN.

Equipment and Software

Equipment/Software Release/Version
Avaya Communication Server 1000E 7.6
Avaya 1140E IP Telephone 4.3 SP1
Zenitel STENTOFON Turbine Intercom Software version: 02.03.3.2

Configure Avaya Communication Server 1000E

The configuration operations illustrated in this section are performed using terminal access to the CS1000E over an SSH session. It is implied a working system is already in place and the SIP Line Gateway (SLG) is fully configured. For all other provisioning information such as installation and configuration, please refer to the Avaya product documentation.

Configuring Data block: SLS (SIP Line Services)

Create an SLS Data block using the change command in Overlay 15. Type LD 15 to enter the overlay. The User Agent Prefix (UAPR) is required when configuring the UEXT for each Stentofon Turbine.

LD 15

Prompt     Response        Description
>LD 15                        Enter Overlay 15
REQ           CHG             Change
TYPE          SLS_DATA        SIP Line Services Data block
CUST          0               Customer Number
SIPL_ON       YES             SIP Line on
UAPR          27              Prefix used to auto-generate the User Agent
NMME          NO              Multimedia Service

Configuring Universal Extension (UEXT)

Configure the UEXT on the CS1000E using the NEW command in overlay 11. Type LD 11 to enter the overlay. At the Key 01 prompt use UAPR as configured in the SLS_DATA Block in the previous section. The SIP User (SIPU) and Station control Password (SCPW) are required when configuring each Stentofon Turbine.

LD 11

Prompt     Response        Description
>             LD 11           Enter Overlay 11
REQ:          NEW             Create New 
TYPE:         UEXT            Universal Extension
TN            100 0 02 00     Terminal Number
DES           SIPL            Description
CUST          0               Customer Number
UXTY          SIPL            Universal Extension Type
MCCL          YES             Maximum Client Count Limit
SIPN          0               SIP Line for Nortel
SIP3          1               SIP Line for third-party
FMCL          0               Fixed Mobility Converged Line
SIPU          3020            Required for Stentofon Turbine USER ID
NDID          163             Node ID
SUPR          NO              Super User
ZONE          1               Bandwidth Zone assigned for IP Sets
SCPW          1234            Required for Stentofon Turbine USER Password
KEY 00        SCR 3020 0      Key 0
CPND          New             Calling Party Name Disply
Name          Stentofon2030   Name
Key 01        HOT U 273020    The HOT U number is derived from the UAPR as 
configured in the SLS_Data plus the Key 0 extension
Key 02