Situation
Calls from the guard station to the cell stations should be rejected unless the cell has made a Call Request to the guard.
Solution
Use the event type “Call Requester Mode” on the cell stations to set/reset call forwarding to a 'dummy' (non-existing) subscriber.
- The text of the 'dummy' subscriber could be ‘Rejected’.
- Number of rings on call forwarding should be set to 0. Go to Exchange & System -> System -> Calls and Options and set Call Forwarding – Ringing Count to 0.
- Feature Reminder (blink’n bleep) should be disabled for the cells. Go to Users & Stations -> User Preferences and tick off Feature Reminder.
In AlphaPro, go to Exchange and System -> Events, press Insert and create the following events:
Event 1: Set transfer to 'dummy' number 345 when not in Call Requester Mode.
Action commands:
$TRF L%1.dir “I345”
Event 2: Reset transfer when in Call Requester Mode.
Action commands:
$TRF L%1.dir “”