Actions

Event Trigger (Event Type)

From Zenitel Wiki

Revision as of 22:10, 9 January 2008 by Asle (talk) (Subevents)

Event description

Event Owner: A station or UDP group
Event type: 15 - Event trigger feature
Subevent: See below
When change to ON: When dialing a directory number with feature 52, 85, 95 or 105
When change to OFF: When feature 95 or 105 disconnects
When related to: The event trigger directory number

Event triggers

  • Feature 52 (9534): Event trigger without cancel tone
  • Feature 85 (9533): Event trigger with cancel tone
  • Feature 95 (9535): Event trigger with directory number parameter
  • Feature 105 (9545): Event trigger with digit parameter

Feature 52 and 85 triggers the ON event only

Subevents

  • The parameter 1 of the Event Trigger directory number (52/n or 85/n) must match the sub-event
  • Example: Feature 85/2 will trigger event type 15, sub-event 2
  • The parameter 1 can be used to group event triggers by filtering on subevent type

Application

  • Any function or combination of functions which is not supported by the standard features in the AlphaCom