Difference between revisions of "Faulty Station Line (Event Type)"
From Zenitel Wiki
(→Additional information) |
(→Event description) |
||
Line 17: | Line 17: | ||
|- | |- | ||
|} | |} | ||
− | <br> | + | <br> |
+ | |||
== Application== | == Application== | ||
Switch over a PA-system to a standby circuit | Switch over a PA-system to a standby circuit |
Revision as of 02:00, 4 November 2007
Event description
Event Owner: | A station or an UDP group |
Event type: | 13 - Faulty station line |
Subevent: | N/A |
When change to ON: | A station's line monitoring has found a problem or if the whole ASLT board becomes faulty |
When change to OFF: | A station's line monitoring has found the station OK |
When related to: | N/A |
Application
Switch over a PA-system to a standby circuit
Additional information
There is also a default "Faulty Line" event, which becomes active if one more stations are faulty. This event is used for general line error reporting. The reporting is configured from AlphaPro, Exchange & System -> RCI -> Faults: Faulty Line. Default setting is MST 1 0 28, which is by reporting line errors (28) to station 1.