Actions

Flowire

From Zenitel Wiki

Revision as of 13:38, 31 May 2018 by Asle (talk | contribs)
APS.png
TCIS-1

Flowire is based on the HomePlug AV power line communications specification, only using 24 - 48 V DC as the medium. It is a network bridge between Ethernet and a PLC link.

There are two variants

  • FCDC-1 (1008080110 ) - Forwards power to the spare pairs of the Ethernet port
  • FCDC-2 (1008080210) - Does not forward power to the Ethernet port
Note icon FCDC-1 forwards the power from the Power Supply Unit. This is not true PoE (Power over Ethernet) technology


Factory defaults

  • Static IP address : 169.254.1.10
  • DHCP enabled. If obtain an dynamic address, it comes in addition to the static address.
  • NMK Password: HomePlugAV0123

MAC address range: 00:13:CB:0A:00:00 -> 00:13:CB:0A:80:00

Reset to Factory defaults

Flowire can be reset to Factory defaults by pressing the button for 15 seconds. The recessed button is located next to the Ethernet connector. (Handled by managerd process.)