Actions

Difference between revisions of "Group Call - Increased volume"

From Zenitel Wiki

Line 3: Line 3:
 
Minimum software is AMC version 11.
 
Minimum software is AMC version 11.
  
In the following example a door station (101) is making a group call with repeatative gong to group 4. The members in group 4 also needs to be members of UDP group 7.
+
In the following example the volume will be set to level 6 when group call 86 is called from stations in UDP group 2. The volume is set to level 3 (default) when the group call is ended.
In [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|Exchange and System -> Events]], press Insert and create the following events:
+
 
 +
In [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|Exchange and System -> Events]], press Insert and create the following event:
  
 
------------
 
------------

Revision as of 16:16, 2 June 2015

This article describes how to increase the volume of a group call announcement. The volume is set back to default value when the group call is ended.

Minimum software is AMC version 11.

In the following example the volume will be set to level 6 when group call 86 is called from stations in UDP group 2. The volume is set to level 3 (default) when the group call is ended.

In AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:


Event Owner: Station Id: Id: 1 (101 The Door)
Event type: 08 - Conversation Outgoing
Sub event: 0
When change to: ON or OFF
When related to: Directory Number, Id: 86
Action:  
IF %chg(1,0)
tmp 0 "%gns(%2.phy,0)"
LOOP
IF %op(%tmp(0),=,0)
STOP
ENDIF
$VOL N%tmp(0) U6
tmp 0 "%gns(%2.phy, %tmp(0))"
ENDLOOP
stop
ENDIF
tmp 0 "%gns(%2.phy,0)"
LOOP
IF %op(%tmp(0),=,0)
STOP
ENDIF
$VOL N%tmp(0) U3
tmp 0 "%gns(%2.phy, %tmp(0))"
ENDLOOP