Actions

Difference between revisions of "High Availability Exchange"

From Zenitel Wiki

(Hardware control)
(Switching of master)
Line 26: Line 26:
  
 
===Switching of master===
 
===Switching of master===
The active AMC board is only switched when a standby card status is reported OK and the master is setting the "Standby request" flag. <br\>
+
The active AMC-IP card is switched only when the standby AMC-IP card status is reported OK and the master is setting the "Standby request" flag. <br\>
  
 
The standby request flag is set when:
 
The standby request flag is set when:
Line 37: Line 37:
  
 
Due to boot of Linux the switch between the AMC cards takes approx 1 min and 30 seconds.
 
Due to boot of Linux the switch between the AMC cards takes approx 1 min and 30 seconds.
 
  
 
===Redundant power supplies===
 
===Redundant power supplies===

Revision as of 11:31, 13 August 2009

Standby AMC-IP

The AlphaCom E20 and AlphaCom E26 exchanges can be equipped with a second AMC-IP card. Both AMC-IP cards are under control of the APC-card and report failure information to the APC, which for this purpose is equipped with a microcontroller. Based on that information the APC decides if and when to switchover between the 2 AMC-IP cards. This means that in the case of an AMC-IP card failure the down time of an E26 exchange is reduced to the time it takes for the standby AMC-IP card to take over rather than the time to get a new card from stock, program it and install it, which even if the card is an on-site spare, will easily take 30 minutes.

Hardware control

The supervisor of the system is a microprocessor plugged in on the APC card. The APC processor monitors the two AMC-IP cards by a dedicated I2C bus controlling some dedicated hardware I/O on the AMC-IP card. The two AMC-IP cards must be placed in board position 24 and 25.

Both AMC-IP cards can be configured with the exact same backup.bin database (also same IP adresses).

AMC status/events controlled by the APC (read by AMC):

  1. Standby/Master mode. In standby mode the MBI and Eth 1 are deactivated.
  2. Trig HW-reset of the AMC card.

Status set by AMC read by the APC:

  1. Card is doing a HW-reset.
  2. Standby request. When not set it means: "I am doing well and ready for doing my duty".
  3. I WILL become a master. APC will reset current master. (Not used)

AMC master in "standby request" is running as long as the APC card is not taking any action.

License handling

For systems requiring licenses the following rules applies (Available from AMC 10.51):<br\>

  • The AMC-IP in pos 25 must have a legal license
  • The AMC-IP in pos 24 must have no licenses installed (i.e. Free License)

Switching of master

The active AMC-IP card is switched only when the standby AMC-IP card status is reported OK and the master is setting the "Standby request" flag. <br\>

The standby request flag is set when:

  • Hardware reset of the master card (Watch dog)
  • Software reset of the master card
  • Hot swap cable use on the master card
  • If all connections to IP stations are lost after reaching the IP station registration trigger level.
  • If the Stentofon Multidrop protocol fails. (This protocol can be active on both active and standby card)


Due to boot of Linux the switch between the AMC cards takes approx 1 min and 30 seconds.

Redundant power supplies

The AlphaCom E26 always has had support for redundant power supplies. This redundancy was supported by the old 1009701000 PSU, and is now supported by the 1009703000. Note that the power supplies operate in load sharing mode which increases the reliability even further, as each PSU is only loaded far below its capability, giving a much lower stress on the compents than for which they are designed.

Note that the redundant AMC-IP solution can also be use in an AlphaCom E20 exchange; this exchange however does not support redundant power supplies.

Ordering information

The components required for the AlphaCom High Availability exchange are available under the following numbers:

  • 1009626010: High Availability exchange, dual AMC-IP with automatic switch over and 2 PSU's; additional AMC-IP filter card is included
  • 1009626011: E26 High Availability extension package, AMC-IP card (including filtercard) and APC upgrade kit