Actions

Hot-plug

From Zenitel Wiki

Revision as of 15:34, 31 August 2018 by Asle (talk | contribs)
AlphaCom icon 300px.png
Hot-plug

In the AlphaCom XE20 and XE26 exchanges, all boards may be inserted or removed without switching off the power by inserting the powered RJ45 plug from the APC board in the hot-plug receptor found at the top of all cards prior to removal or insertion.

  • Remove the hot-plug when the board is in place.

In an AlphaCom XE7 exchange, the power must be switched off prior to removal or insertion of boards as this exchange does not have the APC board or hot-plug feature.

Note icon It is strongly recommended to wear a grounded wrist strap when handling electronic boards to avoid electrostatic discharges that may seriously damage the electronic circuits!