== By a power boot sequence == | == By a power boot sequence == | ||
− | + | The Factory Default procedure can be used to either set the station to use a Static IP address, or to use IP address from a DHCP server. | |
+ | |||
+ | === Restore with Static IP === | ||
+ | [[File:Load Defaults without Display - 1.PNG|right|300px]] | ||
+ | # Press and hold the Privacy button. Power up the station | ||
+ | # When the station LED starts blinking, release the privacy button '''after exactly 2 blinks'''. | ||
+ | # Let the LED blink for '''exactly 2 more times''', then press the button again. | ||
+ | # Keep the button pressed until the LED '''blinks fast 2 times''' indicating a successful reset with static IP. | ||
+ | # Release the button and the station will restart with the factory default settings. | ||
+ | |||
+ | {| class="wikitable" | ||
+ | !style="background:#ffdead" colspan="2"|Factory default values | ||
+ | |- | ||
+ | | Station Mode || align=center | '''Pulse''' | ||
+ | |- | ||
+ | | Station IP address || align=center | '''169.254.1.100''' | ||
+ | |- | ||
+ | | AlphaCom IP address || align=center | '''169.254.1.5''' | ||
+ | |- | ||
+ | | Username* || align=center | '''admin''' | ||
+ | |- | ||
+ | | Password* || align=center | '''alphaadmin''' | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | * Software 01.06 and earlier: '''ADMIN/alphacom''') | ||
+ | |||
+ | === Restore with Activated DHCP === | ||
+ | [[File:Load Defaults without Display - 2.PNG|right|300px]] | ||
+ | The DHCP option is available from software version 01.07.<br/> | ||
+ | * While pressing the call button, power up the substation. | ||
+ | * When the substation LED starts blinking, release the call button '''after exactly 2 blinks'''. | ||
+ | * Let the LED blink for '''exactly 4 more times''', then press the button again. | ||
+ | * Keep the button pressed until the LED '''blinks fast 4 times''' indicating a successful reset with activated DHCP. | ||
+ | * Release the button and the substation will restart with the factory default settings. | ||
+ | |||
+ | {| class="wikitable" | ||
+ | !style="background:#ffdead" colspan="2"|Factory default values | ||
+ | |- | ||
+ | | Station Mode || align=center | '''Pulse''' | ||
+ | |- | ||
+ | | Station IP address || align=center | '''determined by DHCP server''' | ||
+ | |- | ||
+ | | AlphaCom IP address || align=center | '''169.254.1.5''' | ||
+ | |- | ||
+ | | Username* || align=center | '''admin''' | ||
+ | |- | ||
+ | | Password* || align=center | '''alphaadmin''' | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | * Software 01.06 and earlier: '''ADMIN/alphacom''') | ||
+ | |||
+ | |||
[[Category: INCA - Restore Factory Defaults and Software Upgrade]] | [[Category: INCA - Restore Factory Defaults and Software Upgrade]] |
Revision as of 17:01, 16 March 2017
The IP DualDisplay station can be reset to Factory Default settings in two ways:
- From the display menu
- By a power boot sequence
Contents
The Station Menu is available when the IP Station is in offline mode. i.e. not registered to the server.
- Press the Setup button beneath the display
- Enter the password 1851 and press the Ok button.
- Navigate to Load defaults and press the Sel button.
- Press the Sel button to load factory defaults.
The station will now restart with factory settings.
By a power boot sequence
The Factory Default procedure can be used to either set the station to use a Static IP address, or to use IP address from a DHCP server.
Restore with Static IP
- Press and hold the Privacy button. Power up the station
- When the station LED starts blinking, release the privacy button after exactly 2 blinks.
- Let the LED blink for exactly 2 more times, then press the button again.
- Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
- Release the button and the station will restart with the factory default settings.
Factory default values | |
---|---|
Station Mode | Pulse |
Station IP address | 169.254.1.100 |
AlphaCom IP address | 169.254.1.5 |
Username* | admin |
Password* | alphaadmin |
* Software 01.06 and earlier: ADMIN/alphacom)
Restore with Activated DHCP
The DHCP option is available from software version 01.07.
- While pressing the call button, power up the substation.
- When the substation LED starts blinking, release the call button after exactly 2 blinks.
- Let the LED blink for exactly 4 more times, then press the button again.
- Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
- Release the button and the substation will restart with the factory default settings.
Factory default values | |
---|---|
Station Mode | Pulse |
Station IP address | determined by DHCP server |
AlphaCom IP address | 169.254.1.5 |
Username* | admin |
Password* | alphaadmin |
* Software 01.06 and earlier: ADMIN/alphacom)