Actions

Difference between revisions of "INCA IP DualDisplay Station - Restore Factory Defaults"

From Zenitel Wiki

(Restore with Activated DHCP)
Line 48: Line 48:
 
*Password: '''alphaadmin'''
 
*Password: '''alphaadmin'''
  
=== Restore with Activated DHCP ===
 
[[File:Load Defaults without Display - 2.PNG|right|300px]]
 
The DHCP option is available from software version 01.07.<br/>
 
* While pressing the call button, power up the substation.
 
* When the substation LED starts blinking, release the call button '''after exactly 2 blinks'''.
 
* Let the LED blink for '''exactly 4 more times''', then press the button again.
 
* Keep the button pressed until the LED '''blinks fast 4 times''' indicating a successful reset with activated DHCP.
 
* Release the button and the substation will restart with the factory default settings.
 
 
{| class="wikitable"
 
!style="background:#ffdead" colspan="2"|Factory default values
 
|-
 
| Station Mode || align=center | '''Pulse'''
 
|-
 
| Station IP address || align=center | '''determined by DHCP server'''
 
|-
 
| AlphaCom IP address || align=center | '''169.254.1.5'''
 
|-
 
| Username* || align=center | '''admin'''
 
|-
 
| Password* || align=center | '''alphaadmin'''
 
|-
 
|}
 
 
* Software 01.06 and earlier: '''ADMIN/alphacom''')
 
  
  
  
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]

Revision as of 17:04, 16 March 2017

APS.png

The IP DualDisplay station can be reset to Factory Default settings in two ways:

  • From the display menu
  • By a power boot sequence

From the display menu

The Station Menu is available when the IP Station is in offline mode. i.e. not registered to the server.

  • Press the Setup button beneath the display
  • Enter the password 1851 and press the Ok button.
  • Navigate to Load defaults and press the Sel button.
  • Press the Sel button to load factory defaults.
Load Defaults in IP Display Station - 1.PNG
Load Defaults in IP Display Station - 2.PNG

The station will now restart with factory settings.

By a power boot sequence

The Factory Default procedure can be used to either set the station to use a Static IP address, or to use IP address from a DHCP server.

Restore with Static IP

Load Defaults without Display - 1.PNG
  1. Press and hold the Privacy button. Power up the station
  2. When the station LED starts blinking, release the privacy button after exactly 2 blinks.
  3. Let the LED blink for exactly 2 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
  5. Release the button and the station will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100
  • Username: admin
  • Password: alphaadmin

Restore with DHCP enabled

Load Defaults without Display - 1.PNG
  1. Press and hold the Privacy button. Power up the station
  2. When the station LED starts blinking, release the privacy button after exactly 2 blinks.
  3. Let the LED blink for exactly 4 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with DHCP.
  5. Release the button and the station will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: From DHCP server
  • Username: admin
  • Password: alphaadmin