Actions

Difference between revisions of "INCA IP DualDisplay Station - Restore Factory Defaults"

From Zenitel Wiki

(Load factory defaults via power boot sequence)
Line 22: Line 22:
  
 
== Load factory defaults via power boot sequence ==
 
== Load factory defaults via power boot sequence ==
 
+
[[File:DualDisplay Privacy.png|thumb|300px|right|Location of the Privacy button]]
 
The unit can be set to use either '''Static IP''' or '''DHCP'''. Pay attention to the station LED during the restore procedure:
 
The unit can be set to use either '''Static IP''' or '''DHCP'''. Pay attention to the station LED during the restore procedure:
  
Line 30: Line 30:
 
# Keep the button pressed until the LED '''flashes fast 2 times''' (Static IP) or '''flashes fast 4 times''' (DHCP) indicating a successful reset.
 
# Keep the button pressed until the LED '''flashes fast 2 times''' (Static IP) or '''flashes fast 4 times''' (DHCP) indicating a successful reset.
 
# Release the button and the station will restart with the factory default settings.
 
# Release the button and the station will restart with the factory default settings.
 
  
  
Line 38: Line 37:
 
*Username: '''admin'''
 
*Username: '''admin'''
 
*Password: '''alphaadmin'''
 
*Password: '''alphaadmin'''
 
-----------------
 
 
 
The Factory Default procedure can be used to either set the station to use a Static IP address, or to use IP address from a DHCP server.
 
 
=== Restore with Static IP ===
 
[[File:DualDisplay Privacy.png|thumb|300px|right|Location of the Privacy button]]
 
# Press and hold the '''Privacy button'''. Power up the station
 
# When the station LED starts blinking, release the privacy button '''after exactly 2 blinks'''.
 
# Let the LED blink for '''exactly 2 more times''', then press the button again.
 
# Keep the button pressed until the LED '''blinks fast 2 times''' indicating a successful reset with static IP.
 
# Release the button and the station will restart with the factory default settings.
 
 
Factory default values:
 
*Station Mode: '''Pulse'''
 
*Station IP address: '''169.254.1.100'''
 
*Username: '''admin'''
 
*Password: '''alphaadmin'''
 
 
=== Restore with DHCP enabled ===
 
# Press and hold the Privacy button. Power up the station
 
# When the station LED starts blinking, release the privacy button '''after exactly 2 blinks'''.
 
# Let the LED blink for '''exactly 4 more times''', then press the button again.
 
# Keep the button pressed until the LED '''blinks fast 4 times''' indicating a successful reset with DHCP.
 
# Release the button and the station will restart with the factory default settings.
 
 
Factory default values:
 
*Station Mode: '''Pulse'''
 
*Station IP address: '''From DHCP server'''
 
*Username: '''admin'''
 
*Password: '''alphaadmin'''
 
 
  
  
  
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]

Revision as of 14:37, 17 March 2017

APS.png

The IP DualDisplay station can be reset to Factory Default settings in two ways:

  • From the display menu
  • By a power boot sequence

Load factory defaults via the display menu

The Station Menu is available when the IP Station is in offline mode. i.e. not registered to the server.

  • Press the Setup button beneath the display
  • Enter the password 1851 and press the Ok button.
  • Navigate to Load defaults and press the Sel button.
  • Press the Sel button to load factory defaults.
Load Defaults in IP Display Station - 1.PNG
Load Defaults in IP Display Station - 2.PNG

The station will now restart with factory settings:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100
  • Username: admin
  • Password: alphaadmin

Load factory defaults via power boot sequence

Location of the Privacy button

The unit can be set to use either Static IP or DHCP. Pay attention to the station LED during the restore procedure:

  1. While pressing the Privacy button, power up the station kit and keep the button pressed.
  2. Release the button after exactly 2 flashes of the LED.
  3. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  4. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  5. Release the button and the station will restart with the factory default settings.


Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 or DHCP
  • Username: admin
  • Password: alphaadmin