The IP DualDisplay station can be reset to Factory Default settings in two ways:

  • From the display menu
  • By a power boot sequence

From the display menu

The Station Menu is available when the IP Station is in offline mode. i.e. not registered to the server.

  • Press the Setup button beneath the display
  • Enter the password 1851 and press the Ok button.
  • Navigate to Load defaults and press the Sel button.
  • Press the Sel button to load factory defaults.
Load Defaults in IP Display Station - 1.PNG
Load Defaults in IP Display Station - 2.PNG

The station will now restart with factory settings.

By a power boot sequence

The Factory Default procedure can be used to either set the station to use a Static IP address, or to use IP address from a DHCP server.

Restore with Static IP

Load Defaults without Display - 1.PNG
  1. Press and hold the Privacy button. Power up the station
  2. When the station LED starts blinking, release the privacy button after exactly 2 blinks.
  3. Let the LED blink for exactly 2 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
  5. Release the button and the station will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100
  • Username: admin
  • Password: alphaadmin

Restore with Activated DHCP

Load Defaults without Display - 2.PNG

The DHCP option is available from software version 01.07.

  • While pressing the call button, power up the substation.
  • When the substation LED starts blinking, release the call button after exactly 2 blinks.
  • Let the LED blink for exactly 4 more times, then press the button again.
  • Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
  • Release the button and the substation will restart with the factory default settings.
Factory default values
Station Mode Pulse
Station IP address determined by DHCP server
AlphaCom IP address 169.254.1.5
Username* admin
Password* alphaadmin
* Software 01.06 and earlier: ADMIN/alphacom)