This procedure is applicable for:
 
This procedure is applicable for:
 +
* IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]]
 
* IP Master Station Kit [[IP Master Station Kit - 1008093000|100809300]]
 
* IP Master Station Kit [[IP Master Station Kit - 1008093000|100809300]]
* IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]]
+
 
* [[IP Heavy Duty Station|IP Heavy Duty station 1008072xx0]]
+
<div style="text-align:left;"> <youtube width="300" height="180">WP9m-DG0hMU</youtube>  </div>
  
  
The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.
+
The unit can be set to use either '''Static IP''' or '''DHCP'''. On the rear side of the PCB there is a red status LED. Pay attention to this LED during the restore procedure:
  
Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector.
+
[[File:Load Defaults without KEY.PNG|right|thumb|800px|Connect a push button between pins 1 and 4]]
  
[[File:Load Defaults without KEY.PNG|left]]
+
== Procedure ==
<br style="clear:both;" />
+
# Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector.
 +
# While pressing the button, power up the station kit and keep the button pressed.
 +
# Release the button '''after exactly 2 flashes''' of the LED.
 +
# Let the LED flash for '''exactly 2 more times''' (Static IP) or '''exactly 4 more times''' (DHCP), then press the button again.
 +
# Keep the button pressed until the LED '''flashes fast 2 times''' (Static IP) or '''flashes fast 4 times''' (DHCP) indicating a successful reset.
 +
# Release the button and the station will restart with the factory default settings.
  
== Restore with Static IP ==
 
# While pressing the button, power up the station kit.
 
# When the station kit LED starts blinking, release the button '''after exactly 2 blinks'''.
 
# Let the LED blink for '''exactly 2 more times''', then press the button again.
 
# Keep the button pressed until the LED '''blinks fast 2 times''' indicating a successful reset with static IP.
 
# Release the button and the station kit will restart with the factory default settings.
 
  
Factory default values:
+
== Factory default values ==
 
*Station Mode: '''Pulse'''
 
*Station Mode: '''Pulse'''
*Station IP address: '''169.254.1.100'''
+
*Station IP address: '''169.254.1.100''' or '''DHCP'''
 
*Username: '''admin'''
 
*Username: '''admin'''
 
*Password: '''alphaadmin'''
 
*Password: '''alphaadmin'''
  
* Software 01.06 and earlier: '''ADMIN/alphacom''')
 
 
== Restore with Activated DHCP ==
 
The DHCP option is available from software version 01.07.
 
# While pressing the button, power up the station kit.
 
# When the station kit LED starts blinking, release the button '''after exactly 2 blinks'''.
 
# Let the LED blink for '''exactly 4 more times''', then press the button again.
 
# Keep the button pressed until the LED '''blinks fast 4 times''' indicating a successful reset with activated DHCP.
 
# Release the button and the station kit will restart with the factory default settings.
 
 
{| class="wikitable"
 
!style="background:#ffdead" colspan="2"|Factory default values
 
|-
 
| Station Mode || align=center | '''Pulse'''
 
|-
 
| Station IP address || align=center | '''determined by DHCP server'''
 
|-
 
| AlphaCom IP address || align=center | '''169.254.1.5'''
 
|-
 
| Username* || align=center | '''admin'''
 
|-
 
| Password* || align=center | '''alphaadmin'''
 
|-
 
|}
 
 
* Software 01.06 and earlier: '''ADMIN/alphacom''')
 
  
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]

Latest revision as of 14:25, 15 May 2018

APS.png

This procedure is applicable for:


The unit can be set to use either Static IP or DHCP. On the rear side of the PCB there is a red status LED. Pay attention to this LED during the restore procedure:

Connect a push button between pins 1 and 4

Procedure

  1. Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
  2. While pressing the button, power up the station kit and keep the button pressed.
  3. Release the button after exactly 2 flashes of the LED.
  4. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  5. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  6. Release the button and the station will restart with the factory default settings.


Factory default values

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 or DHCP
  • Username: admin