| align=center| '''station phys.no''' ||align=center|CALL||align=center|0x0008||Sets up a coversation between two users
+
| align=center| '''station phys.no''' ||colspan="3" align=center|1 - 552 = The physical number of the station
 
|-
 
|-
 
|align=center| '''output''' ||align=center|CONN||align=center|0x000A|| Sets up a coversation between two users
 
|align=center| '''output''' ||align=center|CONN||align=center|0x000A|| Sets up a coversation between two users
 
|-
 
|-
|align=center| '''Led no/buzzer''' ||align=center| ||align=center|0x000B|| Positive response from the exchange to CONN_REQUEST
+
|align=center| '''LED no/buzzer''' ||align=center| ||align=center|0x000B|| Positive response from the exchange to CONN_REQUEST
 
|-
 
|-
 
| align=center| '''Ind-type''' ||align=center| ||align=center|0x000E|| The external application acknowledges the CONN_REFERENCE
 
| align=center| '''Ind-type''' ||align=center| ||align=center|0x000E|| The external application acknowledges the CONN_REFERENCE

Revision as of 23:39, 10 November 2007

The IND (INDication) action is used for sending commands to a station. The commands are sent as display data. The following stations are currently using the IND command:

  • CRM IV: Control the LED's in the DAK keys, the internal buzzer or relay, and the backlight of the display
  • DualDisplay station: Control the video-state of the DAK-display
  • Priscom station: Control the outputs used for lamps, cell light, call LED and spare output

The command syntax:

IND <station phys.no> <key no.> <LED no/buzzer> <Ind-type> [state]

Parameter description

Between the command parameters, there must always be a space.

Station Connect Operations

Message CRM IV DualDisplay PrisCom
station phys.no 1 - 552 = The physical number of the station
output CONN 0x000A Sets up a coversation between two users
LED no/buzzer   0x000B Positive response from the exchange to CONN_REQUEST
Ind-type   0x000E The external application acknowledges the CONN_REFERENCE
[state]   0x000D Negative response to CONN_REQUEST


station phys.no:

  • 1-552 = The physical number of the station

key no.:

  • 1-100 = The key number of the DAK-key
  • 1023 = Buzzer
  • 1024 = Display

Led no/buzzer:

If the previous parameter was DAK-key (1 - 100):
  • 1 = Red LED
  • 2 = Green LED
If the previous parameter was Buzzer (1023):
  • 1 = Internal buzzer
  • 2 = External buzzer (relay)
If the previous parameter was Display (1024):
  • 1 = Backlight

Ind-type:

LEDs and display:
  • 1 = continuous (low priority)
  • 2 = slow flash (medium priority)
  • 3 = fast flash (high priority)
Buzzers:
  • 1 = 1 bleep per 8 seconds (low priority)
  • 2 = 1 bleep per 2 seconds (medium priority)
  • 3 = 4 bleeps per second (high priority)
  • 4 = continuous (alarm priority)


[state]:

The brackets [ ] indicate that this command is optional. If nothing is entered in this field, the indication is switched on/off along with the event. By entering OFF, for example, you can set an indication to turn off when the event turns on.
  • ON or OFF (capital letters)

Example

IND  2  23  2  3  ON – Station 2, key 23, turn green led, fast flashing, ON