Actions

Difference between revisions of "IND - Indicator control for CRMIV LEDs, buzzer etc."

From Zenitel Wiki

(Related articles)
Line 120: Line 120:
 
== Related articles ==
 
== Related articles ==
  
The [[SET_IPARCO|$SET_IPRCO]] can be used to activate Remote Control Outputs on IP Stations and IPARIO without having to define the RCO's in the RCO table-
+
The [[SET_IPRCO|$SET_IPRCO]] can be used to activate Remote Control Outputs on IP Stations and IPARIO without having to define the RCO's in the RCO table.
  
 
[[Category:Event Handler]]
 
[[Category:Event Handler]]
 
[[Category:Built-In Action Commands]]
 
[[Category:Built-In Action Commands]]

Revision as of 14:12, 30 October 2013

The IND (INDication) or GIND action is used in the Event Handler for sending commands to a station or a group of stations. The commands are sent as display data. The following stations are currently using the IND command:

  • IP Flush Master and CRM V: Control the LED's in the DAK keys
  • CRM IV: Control the LED's in the DAK keys, the internal buzzer or relay, and the backlight of the display
  • DualDisplay station: Control the video-state of the DAK-display
  • Priscom station: Control the outputs used for lamps, cell light, call LED and spare output
  • IP-ARIO: Control the Error LED and the Radio LED
  • IP Substation: Control relay and spare output
  • Turbine station: Control relay and the 6 additional outputs

Command syntax

IND <station phys.no> <output> <LED no/buzzer> <Ind-type> [state]
GIND <group ind> <output> <LED no/buzzer> <Ind-type> [state]

Between the command parameters, there must always be a space.

<group ind> is the AlphaCom group index number 1-250. (Not the group directory number)

Parameter description:

Station/Parameter phys.no output LED no/buzzer IND-type [state]
IP-ARIO Physical number
1 - 552
1 = Radio LED
2 = Error LED
1 = Red LED (Radio and Error)

2 = Green LED (Radio LED only)

1 = continuous (low priority)

2 = slow flash (medium priority)
3 = fast flash (high priority)

ON or OFF
IP Substation (8022) Physical number
1 - 552
1 = Relay
2 = Spare output
Always "1"
1 = continuous (low priority)

2 = slow flash (medium priority)
3 = fast flash (high priority)

ON or OFF
Turbine station Physical number
1 - 552
7 = Relay
1-6 = Spare outputs
Always "1"
1 = continuous (low priority)

2 = slow flash (medium priority)
3 = fast flash (high priority)

ON or OFF
CRM V and IP Flush Master (8024) Physical number
1 - 552
1-100 = DAK-key number 1 = Red LED

2 = Green LED

1 = continuous (low priority)

2 = slow flash (medium priority)
3 = fast flash (high priority)

ON or OFF
CRM IV Physical number
1 - 552
1-100 = DAK-key number
1023 = Buzzer
1024 = Display backlight
DAK-key:
1 = Red LED
2 = Green LED

Buzzer:

1 = Internal buzzer
2 = External buzzer (relay)

Display backlight:

1 = Backlight
DAK LED's:
1 = continuous (low priority)
2 = slow flash (medium priority)
3 = fast flash (high priority)

Buzzers:

1 = 1 bleep per 8 seconds (low priority)
2 = 1 bleep per 2 seconds (medium priority)
3 = 4 bleeps per second (high priority)
4 = continuous (alarm priority)

Display backlight:

1 = continuous
ON or OFF
DualDisplay Physical number
1 - 552
1-100 = The DAK-key line Always "1" Video-state of the DAK-display:
0 = Normal
1 = Inverse
2 = Slow flash
3 = Fast flash
ON or OFF
PrisCom Physical number
1 - 552
1 - 4 = Lamp outputs
5 - 6 = Spare outputs
7 = Cell light
8 = Call LED
Always "1" Output state:
1 = continuous
2 = slow flash
3 = fast flash
ON or OFF

The state parameter is optional. If nothing is entered in this field, the indication is switched on/off along with the event. By entering OFF, for example, you can set an indication to turn off when the event turns on.

Example

IND  2  23  2  3  ON = Station 2, key 23, turn green led, fast flashing, ON


Related articles