Difference between revisions of "IP-LCM Configuration (AlphaCom mode)"
From Zenitel Wiki
(→Inputs) |
|||
Line 4: | Line 4: | ||
* 6 inputs on the The [[TKIS-2]] module itself | * 6 inputs on the The [[TKIS-2]] module itself | ||
* 8 inputs on the IP-LCM board | * 8 inputs on the IP-LCM board | ||
− | |||
[[File:IP-LCM Inputs.png|thumb|left|600px]] | [[File:IP-LCM Inputs.png|thumb|left|600px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
+ | |||
+ | * The inputs on the TKIS-2 module are triggered by connecting the Input to GND. | ||
+ | * Depending on switch settings the inputs on the IP-LCM board are triggerd either by a close contact (default), or by a DC voltage signal. See [[IP-LCM Connections]] for details. |
Revision as of 13:24, 17 April 2019
Inputs
The IP-LCM module has in total 14 inputs:
- 6 inputs on the The TKIS-2 module itself
- 8 inputs on the IP-LCM board
- The inputs on the TKIS-2 module are triggered by connecting the Input to GND.
- Depending on switch settings the inputs on the IP-LCM board are triggerd either by a close contact (default), or by a DC voltage signal. See IP-LCM Connections for details.