Actions

Difference between revisions of "IP-LCM Connections"

From Zenitel Wiki

(Outputs)
(Outputs)
Line 15: Line 15:
  
 
[[File:IPLCM Outputs.PNG|thumb|400px|none|IP-LCM relays]]
 
[[File:IPLCM Outputs.PNG|thumb|400px|none|IP-LCM relays]]
 
  
 
* '''Left position''': Contact Set #1 provides dry contacts.  
 
* '''Left position''': Contact Set #1 provides dry contacts.  
Line 26: Line 25:
 
* '''Switching Current''': < 8A rated (15A max, 4s)
 
* '''Switching Current''': < 8A rated (15A max, 4s)
  
 
+
== External Power Supply ==
 +
The external power supply is required only when you need to forward power via relays 5 - 8. This is the only purpose of the power supply.
  
  
 
See here for for information on the [[TKIS Connections|TKIS-2 kit connections]]
 
See here for for information on the [[TKIS Connections|TKIS-2 kit connections]]

Revision as of 14:13, 11 January 2019

Connector overview

IP-LCM connectors

Inputs

There are 8 inputs. Each of them has a corresponding selector switch, with which one can select between a dry closing contact or an active input.

  • Left position: The input requires an active signal, typically 5V, 12V or 24VDC. The input is galvanic isolated with an opto-coupler. Polarity as indicated on the drawing.
  • Right position: The input requires a dry contact

Outputs

There are 8 relays, each with two sets of changeover contacts (DPDT). The contact terminals, Normally Open (NO), Normally Closed (NC) and Common (COM), are labeled in the silk print of the PCB.

Each output has a LED which indicates if the relay is active or not.

Relay 5 to 8 has a corresponding output selector switch. With this switch one can select if the Contact Set #1 should provide dry contacts, or if it should forward power from the power forwarding connector. Contact Set #2 will always provide dry contacts, regardless of the position of the output selector switch.

IP-LCM relays
  • Left position: Contact Set #1 provides dry contacts.
  • Right position: Contact Set #1 forwards power from the an external power supply connected to the IP-LCM unit. When the PSU is connected with the polarity as indicated in the drawing above, the "+" will appear on the Com terminal, and the "-" will appear on the NO-terminal when the relay is active. When the relay is in idle, the "-" will appear on the NC-terminal.

Relay contact ratings:

  • Outputs: DPDT (Double Pole Double Throw). NO (Normal Open), NC (Normal Closed), COM (Common)
  • Switched voltage: < 250VAC Rated (400VAC Max)
  • Switched Voltage: < 2000 VA max
  • Switching Current: < 8A rated (15A max, 4s)

External Power Supply

The external power supply is required only when you need to forward power via relays 5 - 8. This is the only purpose of the power supply.


See here for for information on the TKIS-2 kit connections