Actions

Difference between revisions of "IP Flush Master -V2 Board Connectors"

From Zenitel Wiki

(J10 - Microphone)
(J11, J12 & J13 - Handset)
Line 33: Line 33:
 
* ''When "Station Type" is set as '''Master station''' in AlphaPro, the inputs are mapped as DAK '''11, 12''' and '''13'''.''
 
* ''When "Station Type" is set as '''Master station''' in AlphaPro, the inputs are mapped as DAK '''11, 12''' and '''13'''.''
 
* ''When the "Station Type" is set as '''CRM''' in AlphaPro, the inputs are mapped as '''251, 252''' and '''253'''.'' }}
 
* ''When the "Station Type" is set as '''CRM''' in AlphaPro, the inputs are mapped as '''251, 252''' and '''253'''.'' }}
 
====J11, J12 & J13 - Handset====
 
Pin header for handset connection. Same as J8 pin 1 - 6.
 
[[File:IPFlushMasterPCB J11-13.png|left|thumb|400px|J11, J12, J13]]
 
<br style="clear:both;" />
 
 
*J11  Pin 1  Spk+
 
*J11  Pin 2  Spk-
 
*J12  Pin 1  Mic+
 
*J12  Pin 2  Mic-
 
*J13  Pin 1  OFFHOOK
 
*J13  Pin 2  GND
 
  
 
====S1 - Microphone Selection====
 
====S1 - Microphone Selection====

Revision as of 15:10, 23 June 2023

AEIS.png

This chapter gives details about connections and indications for:

IPFlushMasterKitPCB2.png

P1 - LAN port & P2 AUX port

P1:

LAN connector for 10/100 Mbit Ethernet connection. The station can be powered from this connection if the line supports Power over Ethernet (PoE).

The connector has two LEDs in front where the right (R) LED indicates Ethernet speed and the left (L) LED verifies Ethernet link and traffic. (L and R as seen from the connector side)

P2:

RJ45 connector for auxiliary equipment like IP camera, PC or a second IP station. This port does not have an individual IP address. It does not carry power for AUX equipment.

P1/P2


P4 - Inputs and Station LED

6-pin plug-on screw terminal for external connections.

P4


  • Pin 1/4 Input 1
  • Pin 2/4 Input 2
  • Pin 3/4 Input 3
  • Pin 5/6 Station LED for call message info.
Note icon
  • When "Station Type" is set as Master station in AlphaPro, the inputs are mapped as DAK 11, 12 and 13.
  • When the "Station Type" is set as CRM in AlphaPro, the inputs are mapped as 251, 252 and 253.


S1 - Microphone Selection

Slide-switch to select internal microphone (Int) or gooseneck microphone (Ext).

S1